Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1991 |
Principal Product | SNACK FOOD |
NAICS | n/a |
SIC | 2096 - Potato Chips And Similar Snacks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 450 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 100,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $964,603 | 25,216,003 | kWh | $0.04 |
Natural Gas | $499,878 | 345,073 | MMBtu | $1.45 |
Coal | $353,233 | 191,163 | MMBtu | $1.85 |
TOTAL ENERGY COSTS | $1,817,714 | |||
RECOMMENDED SAVINGS* | $89,256 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $65,047 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Coal | Administrative Changes | Electricity Usage | Natural Gas | Coal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $41,503 Cost: $2,000 |
- | - | $14,783 | 14,080 | $26,720 | 14,443 | - | - |
- - kWh |
$14,783 14,080 MMBtu |
$26,720 14,443 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,123 Cost: $9,103 |
$5,123 | 136,284 | - | - | - | - | - | - |
$5,123 136,284 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $14,515 Cost: - |
- | - | - | - | - | - | $14,515 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$14,515 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,735 Cost: $35,163 |
$11,735 | - | - | - | - | - | - | - |
$11,735 - kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $9,694 Cost: - |
- | - | - | - | - | - | $9,694 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$9,694 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,996 Cost: - |
$6,010 | 162,075 | - | - | - | - | $(-3,014) | - |
$6,010 162,075 kWh |
- - MMBtu |
- - MMBtu |
$(-3,014) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,544 Cost: $700 |
- | - | $3,544 | 3,375 | - | - | - | - |
- - kWh |
$3,544 3,375 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $146 Cost: $250 |
- | - | $146 | 139 | - | - | - | - |
- - kWh |
$146 139 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $89,256 Cost: $47,216 |
$22,868 | 298,359 | $18,473 | 17,594 | $26,720 | 14,443 | $21,195 | - | $22,868 298,359 kWh |
$18,473 17,594 MMBtu |
$26,720 14,443 MMBtu |
$21,195 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $65,047 Cost: $47,216 |
$22,868 | 298,359 | $18,473 | 17,594 | $26,720 | 14,443 | $(-3,014) | - | $22,868 298,359 kWh |
$18,473 17,594 MMBtu |
$26,720 14,443 MMBtu |
$(-3,014) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Coal | Administrative Changes | Electricity Usage | Natural Gas | Coal | Administrative Changes |