Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Notre Dame Univ.
Assessment Year 1994
Principal Product kitchen cabinets
NAICS n/a
SIC 2434 - Wood Kitchen Cabinets
Sales $10,000,000-$50,000,000
# of Employees 400
Plant Area (Sq.Ft.) 300,000
Annual Production 400,000 Pieces
Production Hrs. Annual 4,575
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $387,482 8,131,594 kWh $0.05
Natural Gas $98,232 21,379 MMBtu $4.59
Coal $28,944 15,196 MMBtu $1.90
TOTAL ENERGY COSTS $514,658
RECOMMENDED SAVINGS* $77,116 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $40,040
#|Description Savings
Cost
Status Electricity Usage Natural Gas Coal Electricity Usage Natural Gas Coal
$ kWh $ MMBtu $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$29,083
Cost:
$135,000
- - $15,123 4,583 $13,960 4,230 -
-
kWh
$15,123
4,583
MMBtu
$13,960
4,230
MMBtu
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$18,916
Cost:
$30,800
- - $9,836 2,533 $9,080 2,339 -
-
kWh
$9,836
2,533
MMBtu
$9,080
2,339
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$15,402
Cost:
$900
$15,402 331,770 - - - - $15,402
331,770
kWh
-
-
MMBtu
-
-
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,791
Cost:
$7,970
$7,791 167,351 - - - - $7,791
167,351
kWh
-
-
MMBtu
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,101
Cost:
$1,580
$3,101 66,530 - - - - $3,101
66,530
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,621
Cost:
$260
$2,621 56,272 - - - - $2,621
56,272
kWh
-
-
MMBtu
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$202
Cost:
$690
$202 4,396 - - - - $202
4,396
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$77,116
Cost:
$177,200
$29,117 626,319 $24,959 7,116 $23,040 6,569 $29,117
626,319
kWh
$24,959
7,116
MMBtu
$23,040
6,569
MMBtu
TOTAL IMPLEMENTED Savings:
$40,040
Cost:
$33,540
$21,124 454,572 $9,836 2,533 $9,080 2,339 $21,124
454,572
kWh
$9,836
2,533
MMBtu
$9,080
2,339
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas Coal Electricity Usage Natural Gas Coal