Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Heat and Treat |
NAICS | n/a |
SIC | 3398 - Metal Heat Treating |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 10,000,000 Pounds |
Production Hrs. Annual | 8,424 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $126,822 | 4,199,297 | kWh | $0.03 |
Electricity Demand | $71,549 | 7,636 | kW-months/year | $9.37 |
Natural Gas | $604,334 | 228,586 | MMBtu | $2.64 |
TOTAL ENERGY COSTS | $802,705 | |||
RECOMMENDED SAVINGS* | $9,212 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,318 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $306 Cost: $250 |
$196 | 6,448 | $110 | 12 | - | - | - | - |
$196 6,448 kWh |
$110 12 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $208 Cost: $600 |
$208 | 7,034 | - | - | - | - | - | - |
$208 7,034 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $14 Cost: $252 |
$14 | 586 | - | - | - | - | - | - |
$14 586 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,011 Cost: $570 |
$630 | 21,688 | $381 | 41 | - | - | - | - |
$630 21,688 kWh |
$381 41 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,672 Cost: $6,376 |
- | - | $4,585 | - | $3,087 | - | - | - |
- - kWh |
$4,585 - kW-months/year |
$3,087 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $1 Cost: - |
- | - | - | - | - | - | $1 | 314 |
- - kWh |
- - kW-months/year |
- - $ |
$1 314 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $9,212 Cost: $8,048 |
$1,048 | 35,756 | $5,076 | 53 | $3,087 | - | $1 | 314 | $1,048 35,756 kWh |
$5,076 53 kW-months/year |
$3,087 - $ |
$1 314 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,318 Cost: $820 |
$826 | 28,136 | $491 | 53 | - | - | $1 | 314 | $826 28,136 kWh |
$491 53 kW-months/year |
- - $ |
$1 314 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal |