Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | heaters |
NAICS | n/a |
SIC | 3433 - Heating Equipment, Except Electric |
Sales | $1,000,000-$5,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 34,400 |
Annual Production | 3,000,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $82,816 | 1,260,258 | kWh | $0.07 |
Electricity Demand | $21,196 | 2,522 | kW-months/year | $8.40 |
Electricity Fees | $(-8,976) | - | $ | - |
Natural Gas | $10,067 | 2,444 | MMBtu | $4.12 |
TOTAL ENERGY COSTS | $105,103 | |||
RECOMMENDED SAVINGS* | $9,864 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,073 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,615 Cost: $500 |
$1,178 | 19,050 | $437 | 45 | - | - | - | - | - | - |
$1,178 19,050 kWh |
$437 45 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $562 Cost: $670 |
$365 | 7,034 | $197 | 15 | - | - | - | - | - | - |
$365 7,034 kWh |
$197 15 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $447 Cost: $1,000 |
$447 | 7,327 | - | - | - | - | - | - | - | - |
$447 7,327 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $223 Cost: $67 |
$223 | 3,517 | - | - | - | - | - | - | - | - |
$223 3,517 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8112 COMBINE UTILITY METERS |
Savings: $1,562 Cost: $4,000 |
- | - | - | - | $1,562 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,562 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $285 Cost: $540 |
$209 | 3,224 | $76 | 32 | - | - | - | - | - | - |
$209 3,224 kWh |
$76 32 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $887 Cost: $100 |
$887 | 14,361 | - | - | - | - | - | - | - | - |
$887 14,361 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $167 Cost: $1,000 |
$153 | 2,345 | $58 | 6 | - | - | $(-44) | (-11) | - | - |
$153 2,345 kWh |
$58 6 kW-months/year |
- - $ |
$(-44) (-11) MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $4,116 Cost: $800 |
- | - | - | - | - | - | - | - | $4,116 | 200 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$4,116 200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $9,864 Cost: $8,677 |
$3,462 | 56,858 | $768 | 98 | $1,562 | - | $(-44) | (-11) | $4,116 | 200 | $3,462 56,858 kWh |
$768 98 kW-months/year |
$1,562 - $ |
$(-44) (-11) MMBtu |
$4,116 200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,073 Cost: $2,177 |
$1,684 | 28,136 | $273 | 47 | - | - | - | - | $4,116 | 200 | $1,684 28,136 kWh |
$273 47 kW-months/year |
- - $ |
- - MMBtu |
$4,116 200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |