Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Aluminum clamps |
NAICS | n/a |
SIC | 3429 - Hardware, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 41,000 |
Annual Production | 1,500,000 Pounds |
Production Hrs. Annual | 2,040 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,755 | 495,604 | kWh | $0.06 |
Electricity Demand | $19,900 | 2,416 | kW-months/year | $8.24 |
Natural Gas | $4,098 | 786 | MMBtu | $5.21 |
TOTAL ENERGY COSTS | $55,069 | |||
RECOMMENDED SAVINGS* | $4,793 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,288 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $163 Cost: $597 |
$99 | 1,172 | $64 | 8 | - | - | - | - |
$99 1,172 kWh |
$64 8 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $520 Cost: $882 |
$314 | 5,569 | $206 | 25 | - | - | - | - |
$314 5,569 kWh |
$206 25 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $117 Cost: $57 |
$117 | 1,758 | - | - | - | - | - | - |
$117 1,758 kWh |
- - kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $444 Cost: $560 |
$270 | 4,689 | $174 | 21 | - | - | - | - |
$270 4,689 kWh |
$174 21 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $564 Cost: $1,200 |
$564 | 5,862 | - | - | - | - | - | - |
$564 5,862 kWh |
- - kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,172 Cost: $650 |
$2,172 | 22,274 | - | - | - | - | - | - |
$2,172 22,274 kWh |
- - kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $497 Cost: $200 |
$497 | 5,275 | - | - | - | - | - | - |
$497 5,275 kWh |
- - kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.7214 REDUCE OR ELIMINATE WASTE |
Savings: $316 Cost: $700 |
- | - | - | - | $14 | 80 | $302 | 4,600 |
- - kWh |
- - kW-months/year |
$14 80 gal |
$302 4,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $4,793 Cost: $4,846 |
$4,033 | 46,599 | $444 | 54 | $14 | 80 | $302 | 4,600 | $4,033 46,599 kWh |
$444 54 kW-months/year |
$14 80 gal |
$302 4,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,288 Cost: $2,886 |
$2,702 | 30,773 | $270 | 33 | $14 | 80 | $302 | 4,600 | $2,702 30,773 kWh |
$270 33 kW-months/year |
$14 80 gal |
$302 4,600 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) |