Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Target Missiles |
NAICS | n/a |
SIC | 3489 - Ordnance And Accessories, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 149 |
Plant Area (Sq.Ft.) | 82,000 |
Annual Production | 24 Pieces |
Production Hrs. Annual | 2,625 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $102,364 | 2,235,932 | kWh | $0.05 |
Electricity Demand | $24,670 | 6,920 | kW-months/year | $3.57 |
Natural Gas | $5,961 | 930 | MMBtu | $6.41 |
TOTAL ENERGY COSTS | $152,551 | |||
RECOMMENDED SAVINGS* | $76,327 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,281 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $25,063 Cost: $75,000 |
- | - | - | - | $25,063 | - | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$25,063 - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $19,775 Cost: $7,000 |
$11,673 | 254,982 | $3,102 | 870 | - | - | - | - | - | - | - | - | $5,000 | - | - | - | - | - |
$11,673 254,982 kWh |
$3,102 870 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
$5,000 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,005 Cost: $36,799 |
$5,043 | 109,027 | $1,962 | 550 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$5,043 109,027 kWh |
$1,962 550 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $6,570 Cost: $1,500 |
$6,570 | 142,438 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$6,570 142,438 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,396 Cost: $1,000 |
$2,684 | 58,617 | $712 | 200 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$2,684 58,617 kWh |
$712 200 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,092 Cost: $1,388 |
$436 | 7,620 | - | - | - | - | - | - | - | - | - | - | $324 | - | - | - | $332 | - |
$436 7,620 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
$324 - $ |
- - $ |
$332 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $872 Cost: $400 |
$684 | 14,947 | $188 | 53 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$684 14,947 kWh |
$188 53 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $405 Cost: $1,140 |
$322 | 7,034 | $83 | 23 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$322 7,034 kWh |
$83 23 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $196 Cost: $100 |
$161 | 3,517 | $35 | 10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$161 3,517 kWh |
$35 10 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $174 Cost: - |
$174 | 3,810 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$174 3,810 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $173 Cost: $200 |
$173 | 3,810 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$173 3,810 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $8,276 Cost: $10,000 |
- | - | - | - | - | - | $8,276 | 3,726,994 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,276 3,726,994 Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $450 Cost: - |
- | - | - | - | - | - | - | - | - | - | $450 | 12,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
$450 12,000 lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $300 Cost: $200 |
- | - | - | - | - | - | - | - | $300 | 5 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$300 5 gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,580 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $2,580 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - lb |
- - $ |
$2,580 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,327 Cost: $134,727 |
$27,920 | 605,802 | $6,082 | 1,706 | $25,063 | - | $8,276 | 3,726,994 | $300 | 5 | $450 | 12,000 | $5,324 | - | $2,580 | - | $332 | - | $27,920 605,802 kWh |
$6,082 1,706 kW-months/year |
$25,063 - $ |
$8,276 3,726,994 Tgal |
$300 5 gal |
$450 12,000 lb |
$5,324 - $ |
$2,580 - $ |
$332 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,281 Cost: $46,799 |
$5,043 | 109,027 | $1,962 | 550 | - | - | $8,276 | 3,726,994 | - | - | - | - | - | - | - | - | - | - | $5,043 109,027 kWh |
$1,962 550 kW-months/year |
- - $ |
$8,276 3,726,994 Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |