Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Machines and machined parts |
NAICS | n/a |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 48,500 |
Annual Production | 10,000,000 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $77,133 | 1,071,805 | kWh | $0.07 |
Electricity Demand | $31,076 | 2,726 | kW-months/year | $11.40 |
Natural Gas | $15,212 | 3,831 | MMBtu | $3.97 |
TOTAL ENERGY COSTS | $123,421 | |||
RECOMMENDED SAVINGS* | $13,268 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,533 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,054 Cost: $2,780 |
$2,308 | 58,910 | $1,746 | 153 | - | - | - | - | - | - |
$2,308 58,910 kWh |
$1,746 153 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8221 USE ALTERNATIVES FOR ACIDS / ALKALINE (WATER, STEAM, ABRASIVE) |
Savings: $3,386 Cost: $50 |
- | - | - | - | - | - | - | - | $3,386 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$3,386 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,506 Cost: $582 |
- | - | - | - | $1,506 | 379 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,506 379 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,301 Cost: $500 |
$1,301 | 18,171 | - | - | - | - | - | - | - | - |
$1,301 18,171 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $831 Cost: $200 |
$831 | 11,430 | - | - | - | - | - | - | - | - |
$831 11,430 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $701 Cost: $600 |
$419 | 9,672 | $282 | 25 | - | - | - | - | - | - |
$419 9,672 kWh |
$282 25 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $545 Cost: $53 |
$325 | 7,620 | $220 | 19 | - | - | - | - | - | - |
$325 7,620 kWh |
$220 19 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $312 Cost: - |
- | - | - | - | - | - | - | - | $312 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$312 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $185 Cost: $516 |
- | - | - | - | $185 | 47 | - | - | - | - |
- - kWh |
- - kW-months/year |
$185 47 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $180 Cost: $200 |
- | - | - | - | - | - | $180 | 9 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$180 9 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $135 Cost: - |
- | - | - | - | - | - | - | - | $135 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$135 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $103 Cost: $57 |
- | - | - | - | $103 | 26 | - | - | - | - |
- - kWh |
- - kW-months/year |
$103 26 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $29 Cost: $55 |
$17 | 293 | $12 | 1 | - | - | - | - | - | - |
$17 293 kWh |
$12 1 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,268 Cost: $5,593 |
$5,201 | 106,096 | $2,260 | 198 | $1,794 | 452 | $180 | 9 | $3,833 | - | $5,201 106,096 kWh |
$2,260 198 kW-months/year |
$1,794 452 MMBtu |
$180 9 gal |
$3,833 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,533 Cost: $3,090 |
$3,464 | 77,960 | $1,966 | 172 | $103 | 26 | - | - | - | - | $3,464 77,960 kWh |
$1,966 172 kW-months/year |
$103 26 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost |