Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Orthopedic Instruments |
NAICS | n/a |
SIC | 3841 - Surgical And Medical Instruments |
Sales | $10,000,000-$50,000,000 |
# of Employees | 202 |
Plant Area (Sq.Ft.) | 51,000 |
Annual Production | 77,000 Pounds |
Production Hrs. Annual | 7,344 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $222,457 | 4,183,763 | kWh | $0.05 |
Electricity Demand | $81,508 | 7,858 | kW-months/year | $10.37 |
Electricity Fees | $(-51,171) | - | $ | - |
Natural Gas | $9,814 | 1,846 | MMBtu | $5.32 |
TOTAL ENERGY COSTS | $262,608 | |||
RECOMMENDED SAVINGS* | $15,492 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,492 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,922 Cost: $2,510 |
$1,457 | 27,550 | $465 | 45 | - | - | - | - | - | - |
$1,457 27,550 kWh |
$465 45 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,468 Cost: $338 |
- | - | - | - | - | - | $2,468 | 464 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,468 464 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,452 Cost: $6,303 |
$1,142 | 21,395 | $1,310 | 126 | - | - | - | - | - | - |
$1,142 21,395 kWh |
$1,310 126 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,679 Cost: $80 |
$1,479 | 27,843 | $200 | 19 | - | - | - | - | - | - |
$1,479 27,843 kWh |
$200 19 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,312 Cost: $950 |
$1,168 | 21,981 | $144 | 14 | - | - | - | - | - | - |
$1,168 21,981 kWh |
$144 14 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $911 Cost: $900 |
$420 | 7,913 | $65 | 6 | - | - | - | - | $426 | - |
$420 7,913 kWh |
$65 6 kW-months/year |
- - $ |
- - MMBtu |
$426 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $301 Cost: $208 |
$157 | 4,396 | $105 | 12 | - | - | - | - | $39 | - |
$157 4,396 kWh |
$105 12 kW-months/year |
- - $ |
- - MMBtu |
$39 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $96 Cost: - |
$96 | 1,758 | - | - | - | - | - | - | - | - |
$96 1,758 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $59 Cost: $350 |
- | - | - | - | $59 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$59 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $4,292 Cost: $9,475 |
- | - | - | - | $4,292 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,292 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,492 Cost: $21,114 |
$5,919 | 112,836 | $2,289 | 222 | $4,351 | - | $2,468 | 464 | $465 | - | $5,919 112,836 kWh |
$2,289 222 kW-months/year |
$4,351 - $ |
$2,468 464 MMBtu |
$465 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,492 Cost: $21,114 |
$5,919 | 112,836 | $2,289 | 222 | $4,351 | - | $2,468 | 464 | $465 | - | $5,919 112,836 kWh |
$2,289 222 kW-months/year |
$4,351 - $ |
$2,468 464 MMBtu |
$465 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost |