Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Corrugated Boxes |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 100,000 Thousand Feet |
Production Hrs. Annual | 2,912 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $58,096 | 599,648 | kWh | $0.10 |
Electricity Demand | $40,447 | 3,548 | kW-months/year | $11.40 |
Electricity Fees | $3,730 | - | $ | - |
Natural Gas | $45,432 | 11,566 | MMBtu | $3.93 |
TOTAL ENERGY COSTS | $148,732 | |||
RECOMMENDED SAVINGS* | $17,878 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,695 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $6,421 Cost: $10,400 |
$3,299 | 66,530 | $3,122 | 274 | - | - | - | - | - | - |
$3,299 66,530 kWh |
$3,122 274 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,131 Cost: $9,600 |
- | - | - | - | - | - | $4,131 | 1,152 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,131 1,152 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,791 Cost: $14,171 |
$1,427 | 28,429 | $1,364 | 120 | - | - | - | - | - | - |
$1,427 28,429 kWh |
$1,364 120 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,278 Cost: $3,600 |
$2,278 | 24,912 | - | - | - | - | - | - | - | - |
$2,278 24,912 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.811 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS |
Savings: $868 Cost: $250 |
- | - | - | - | $868 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$868 - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $410 Cost: $180 |
$410 | 4,396 | - | - | - | - | - | - | - | - |
$410 4,396 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $289 Cost: $240 |
$289 | 2,052 | - | - | - | - | - | - | - | - |
$289 2,052 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $256 Cost: $600 |
- | - | - | - | - | - | - | - | $256 | 208,000 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$256 208,000 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7122 DISCONNECT BALLASTS |
Savings: $194 Cost: $176 |
$194 | 2,052 | - | - | - | - | - | - | - | - |
$194 2,052 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $167 Cost: $600 |
$167 | 1,758 | - | - | - | - | - | - | - | - |
$167 1,758 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $73 Cost: $300 |
- | - | - | - | - | - | $73 | 19 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$73 19 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,878 Cost: $40,117 |
$8,064 | 130,129 | $4,486 | 394 | $868 | - | $4,204 | 1,171 | $256 | 208,000 | $8,064 130,129 kWh |
$4,486 394 kW-months/year |
$868 - $ |
$4,204 1,171 MMBtu |
$256 208,000 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,695 Cost: $25,051 |
$5,136 | 99,355 | $4,486 | 394 | - | - | $73 | 19 | - | - | $5,136 99,355 kWh |
$4,486 394 kW-months/year |
- - $ |
$73 19 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal |