Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Notre Dame Univ.
Assessment Year 1999
Principal Product pressure sensitive vinyl film
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 100,000
Annual Production 130,000 Thousand Feet
Production Hrs. Annual 8,568
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $346,701 6,566,530 kWh $0.05
Electricity Demand $111,408 10,887 kW-months/year $10.23
Natural Gas $538,362 185,966 MMBtu $2.89
TOTAL ENERGY COSTS $996,471
RECOMMENDED SAVINGS* $10,126 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$3,558
Cost:
$7,202
$2,702 59,789 $856 84 - - $2,702
59,789
kWh
$856
84
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,941
Cost:
$4,883
$1,732 38,394 $1,209 118 - - $1,732
38,394
kWh
$1,209
118
kW-months/year
-
-
MMBtu
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$729
Cost:
$125
- - $729 71 - - -
-
kWh
$729
71
kW-months/year
-
-
MMBtu
04: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$126
Cost:
$150
$109 2,345 $17 2 - - $109
2,345
kWh
$17
2
kW-months/year
-
-
MMBtu
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$458
Cost:
$400
$325 7,327 $221 22 $(-88) (-31) $325
7,327
kWh
$221
22
kW-months/year
$(-88)
(-31)
MMBtu
06: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$73
Cost:
$90
$63 1,465 $10 1 - - $63
1,465
kWh
$10
1
kW-months/year
-
-
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,241
Cost:
$80
$2,241 49,531 - - - - $2,241
49,531
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$10,126
Cost:
$12,930
$7,172 158,851 $3,042 298 $(-88) (-31) $7,172
158,851
kWh
$3,042
298
kW-months/year
$(-88)
(-31)
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas