Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2018 |
Principal Product | Treated Wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $5,000,000-$10,000,000 |
# of Employees | 9 |
Plant Area (Sq.Ft.) | 1,176,000 |
Annual Production | 1,457,950 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $188,787 | 3,371,200 | kWh | $0.06 |
Electricity Demand | $3,540 | 467 | kW-months/year | $7.58 |
Electricity Fees | $83,723 | - | $ | - |
Natural Gas | $58,883 | 11,341 | MMBtu | $5.19 |
TOTAL ENERGY COSTS | $334,933 | |||
RECOMMENDED SAVINGS* | $38,840 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,540 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $24,300 Cost: $149,000 |
$20,500 | 366,000 | $3,800 | 502 | - | - | - | - | - | - |
$20,500 366,000 kWh |
$3,800 502 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $9,300 Cost: $210 |
$1,800 | 32,142 | $(-320) | (-42) | $7,820 | 1,506 | - | - | - | - |
$1,800 32,142 kWh |
$(-320) (-42) kW-months/year |
$7,820 1,506 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,700 Cost: $2,500 |
$2,958 | 52,800 | - | - | - | - | $380 | - | $362 | - |
$2,958 52,800 kWh |
- - kW-months/year |
- - MMBtu |
$380 - $ |
$362 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,100 Cost: $820 |
$1,100 | 19,643 | - | - | - | - | - | - | - | - |
$1,100 19,643 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $440 Cost: $210 |
$116 | 2,071 | - | - | - | - | $324 | - | - | - |
$116 2,071 kWh |
- - kW-months/year |
- - MMBtu |
$324 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,840 Cost: $152,740 |
$26,474 | 472,656 | $3,480 | 459 | $7,820 | 1,506 | $704 | - | $362 | - | $26,474 472,656 kWh |
$3,480 459 kW-months/year |
$7,820 1,506 MMBtu |
$704 - $ |
$362 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,540 Cost: $3,740 |
$5,974 | 106,656 | $(-320) | (-42) | $7,820 | 1,506 | $704 | - | $362 | - | $5,974 106,656 kWh |
$(-320) (-42) kW-months/year |
$7,820 1,506 MMBtu |
$704 - $ |
$362 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||