Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2018 |
Principal Product | Motor Fan Clutches |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3519 - Internal Combustion Engines, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 155,000 |
Annual Production | 250,000 Units |
Production Hrs. Annual | 5,980 |
Location (State) | SD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $331,584 | 6,960,000 | kWh | $0.05 |
Electricity Demand | $131,403 | 17,071 | kW-months/year | $7.70 |
Electricity Fees | $21,505 | - | $ | - |
LPG | $34,971 | 2,363 | MMBtu | $14.80 |
TOTAL ENERGY COSTS | $525,418 | |||
RECOMMENDED SAVINGS* | $29,931 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,511 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,027 Cost: $132,430 |
$13,410 | 279,381 | $3,710 | 550 | - | - | $1,907 | - | - | - |
$13,410 279,381 kWh |
$3,710 550 kW-months/year |
- - Tgal |
$1,907 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,100 Cost: - |
- | - | $8,100 | 1,200 | - | - | - | - | - | - |
- - kWh |
$8,100 1,200 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $2,484 Cost: $7,000 |
- | - | - | - | - | - | - | - | $2,484 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$2,484 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4155 METER WASTE WATER |
Savings: $320 Cost: - |
- | - | - | - | $320 | 97 | - | - | - | - |
- - kWh |
- - kW-months/year |
$320 97 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,931 Cost: $139,430 |
$13,410 | 279,381 | $11,810 | 1,750 | $320 | 97 | $1,907 | - | $2,484 | - | $13,410 279,381 kWh |
$11,810 1,750 kW-months/year |
$320 97 Tgal |
$1,907 - $ |
$2,484 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,511 Cost: $139,430 |
$13,410 | 279,381 | $3,710 | 550 | - | - | $1,907 | - | $2,484 | - | $13,410 279,381 kWh |
$3,710 550 kW-months/year |
- - Tgal |
$1,907 - $ |
$2,484 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost |