Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1997 |
Principal Product | Steel Doors |
NAICS | n/a |
SIC | 3442 - Metal Doors, Sash, And Trim |
Sales | $100,000,000-$500,000,000 |
# of Employees | 52 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 5,000 Thousand Feet |
Production Hrs. Annual | 3,320 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $75,951 | 1,121,336 | kWh | $0.07 |
Electricity Demand | $28,424 | 3,651 | kW-months/year | $7.79 |
Electricity Fees | $4,784 | - | $ | - |
Natural Gas | $7,066 | 1,223 | MMBtu | $5.78 |
TOTAL ENERGY COSTS | $116,225 | |||
RECOMMENDED SAVINGS* | $130,624 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $75,254 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,967 Cost: $170 |
$2,976 | 43,962 | $991 | 127 | - | - | - | - | - | - |
$2,976 43,962 kWh |
$991 127 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,948 Cost: $1,330 |
- | - | - | - | $2,948 | 510 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,948 510 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,173 Cost: $1,500 |
- | - | - | - | $2,173 | 376 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,173 376 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $872 Cost: $360 |
$750 | 7,620 | $122 | 16 | - | - | - | - | - | - |
$750 7,620 kWh |
$122 16 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $435 Cost: $32 |
$276 | 4,103 | $159 | 20 | - | - | - | - | - | - |
$276 4,103 kWh |
$159 20 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $2,717 Cost: $11,160 |
- | - | - | - | $2,717 | 470 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,717 470 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $1,164 Cost: $2,120 |
$1,203 | 17,878 | $(-39) | (-5) | - | - | - | - | - | - |
$1,203 17,878 kWh |
$(-39) (-5) kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $30,328 Cost: $155,000 |
- | - | - | - | - | - | - | - | $30,328 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$30,328 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $60,656 Cost: $12,000 |
- | - | - | - | - | - | - | - | $60,656 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$60,656 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $15,164 Cost: $20,000 |
- | - | - | - | - | - | - | - | $15,164 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$15,164 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $8,160 Cost: $20,000 |
- | - | - | - | - | - | $8,160 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,160 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.221 USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY |
Savings: $2,040 Cost: - |
- | - | - | - | - | - | $2,040 | 1,013 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,040 1,013 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $130,624 Cost: $223,672 |
$5,205 | 73,563 | $1,233 | 158 | $7,838 | 1,356 | $10,200 | 1,013 | $106,148 | - | $5,205 73,563 kWh |
$1,233 158 kW-months/year |
$7,838 1,356 MMBtu |
$10,200 1,013 lb |
$106,148 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $75,254 Cost: $34,682 |
$5,205 | 73,563 | $1,233 | 158 | - | - | $8,160 | - | $60,656 | - | $5,205 73,563 kWh |
$1,233 158 kW-months/year |
- - MMBtu |
$8,160 - lb |
$60,656 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product |