Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 2000 |
Principal Product | Asphalt |
NAICS | n/a |
SIC | 2951 - Asphalt Paving Mixtures And Blocks |
Sales | $5,000,000-$10,000,000 |
# of Employees | 3 |
Plant Area (Sq.Ft.) | 20,000 |
Annual Production | 250,000 Tons |
Production Hrs. Annual | 925 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $32,203 | 665,885 | kWh | $0.05 |
Electricity Demand | $35,445 | 4,641 | kW-months/year | $7.64 |
Electricity Fees | $5,190 | - | $ | - |
Fuel Oil #2 | $337,849 | 63,091 | MMBtu | $5.35 |
TOTAL ENERGY COSTS | $410,687 | |||
RECOMMENDED SAVINGS* | $207,296 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1114 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE |
Savings: $8,107 Cost: $370 |
- | - | - | - | - | - | $8,107 | 4,090 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,107 4,090 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,666 Cost: $240 |
$6,810 | 152,989 | $5,608 | 734 | $248 | - | - | - | - | - | - | - |
$6,810 152,989 kWh |
$5,608 734 kW-months/year |
$248 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,918 Cost: $8,274 |
$1,172 | 26,377 | $2,669 | 349 | $77 | - | - | - | - | - | - | - |
$1,172 26,377 kWh |
$2,669 349 kW-months/year |
$77 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $4,907 Cost: $2,175 |
- | - | - | - | - | - | $4,907 | 4,292 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,907 4,292 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $880 Cost: $585 |
- | - | - | - | - | - | $880 | 164 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$880 164 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $1,742 Cost: $125 |
$1,742 | 38,394 | - | - | - | - | - | - | - | - | - | - |
$1,742 38,394 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1171 CHANGE PRODUCT SPECS |
Savings: $5,112 Cost: - |
- | - | - | - | - | - | - | - | $5,112 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$5,112 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $169,964 Cost: $15,000 |
$1,967 | 43,962 | - | - | - | - | - | - | - | - | $167,997 | - |
$1,967 43,962 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$167,997 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $207,296 Cost: $26,769 |
$11,691 | 261,722 | $8,277 | 1,083 | $325 | - | $13,894 | 8,546 | $5,112 | - | $167,997 | - | $11,691 261,722 kWh |
$8,277 1,083 kW-months/year |
$325 - $ |
$13,894 8,546 MMBtu |
$5,112 - $ |
$167,997 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Administrative Changes | Primary Product |