Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 2000 |
Principal Product | metal coating |
NAICS | n/a |
SIC | 3479 - Metal Coating And Allied Services |
Sales | $1,000,000-$5,000,000 |
# of Employees | 68 |
Plant Area (Sq.Ft.) | 48,000 |
Annual Production | 1,750,000 Pieces |
Production Hrs. Annual | 4,992 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,715 | 546,000 | kWh | $0.06 |
Electricity Demand | $12,898 | 1,696 | kW-months/year | $7.60 |
Electricity Fees | $325 | - | $ | - |
Natural Gas | $62,259 | 10,556 | MMBtu | $5.90 |
LPG | $108,451 | 11,908 | MMBtu | $9.11 |
TOTAL ENERGY COSTS | $250,700 | |||
RECOMMENDED SAVINGS* | $19,279 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,327 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $12,740 Cost: - |
- | - | - | - | - | - | $12,740 | 2,166 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$12,740 2,166 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $307 Cost: $468 |
$193 | 3,517 | $113 | 15 | $1 | - | - | - | - | - |
$193 3,517 kWh |
$113 15 kW-months/year |
$1 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,699 Cost: $574 |
- | - | - | - | - | - | $1,699 | 289 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,699 289 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $654 Cost: $249 |
$430 | 7,620 | $224 | 29 | - | - | - | - | - | - |
$430 7,620 kWh |
$224 29 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $667 Cost: - |
$502 | 8,792 | $163 | 21 | $2 | - | - | - | - | - |
$502 8,792 kWh |
$163 21 kW-months/year |
$2 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $3,212 Cost: $9,788 |
- | - | - | - | - | - | - | - | $3,212 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$3,212 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,279 Cost: $11,079 |
$1,125 | 19,929 | $500 | 65 | $3 | - | $14,439 | 2,455 | $3,212 | - | $1,125 19,929 kWh |
$500 65 kW-months/year |
$3 - $ |
$14,439 2,455 MMBtu |
$3,212 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,327 Cost: $1,291 |
$1,125 | 19,929 | $500 | 65 | $3 | - | $1,699 | 289 | - | - | $1,125 19,929 kWh |
$500 65 kW-months/year |
$3 - $ |
$1,699 289 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |