Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Old Dominion Univ.
Assessment Year 1995
Principal Product coffee
NAICS n/a
SIC 2095 - Roasted Coffee
Sales $100,000,000-$500,000,000
# of Employees 250
Plant Area (Sq.Ft.) 300,000
Annual Production 145,000,000 Pounds
Production Hrs. Annual 7,056
Location (State) VA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $762,994 16,735,346 kWh $0.05
Natural Gas $330,479 142,084 MMBtu $2.33
TOTAL ENERGY COSTS $1,093,473
RECOMMENDED SAVINGS* $94,692 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,253
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$72,922
Cost:
$168,455
$72,922 1,599,648 $72,922
1,599,648
kWh
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$6,752
Cost:
$83
$6,752 148,007 $6,752
148,007
kWh
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,941
Cost:
$3,025
$4,941 108,148 $4,941
108,148
kWh
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,517
Cost:
$500
$1,517 33,118 $1,517
33,118
kWh
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,560
Cost:
$14,940
$8,560 187,866 $8,560
187,866
kWh
TOTAL RECOMMENDED Savings:
$94,692
Cost:
$187,003
$94,692 2,076,787 $94,692
2,076,787
kWh
TOTAL IMPLEMENTED Savings:
$20,253
Cost:
$18,048
$20,253 444,021 $20,253
444,021
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage