Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Insulation |
NAICS | n/a |
SIC | 3296 - Mineral Wool |
Sales | $10,000,000-$50,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 150 Thousand Feet |
Production Hrs. Annual | 2,080 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $22,013 | 398,300 | kWh | $0.06 |
Electricity Demand | $8,112 | 1,374 | kW-months/year | $5.90 |
Electricity Fees | $2,644 | - | $ | - |
Fuel Oil #2 | $20,076 | 5,022 | MMBtu | $4.00 |
TOTAL ENERGY COSTS | $53,987 | |||
RECOMMENDED SAVINGS* | $4,803 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $690 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $377 Cost: $947 |
$307 | 5,569 | $70 | 12 | - | - | - | - | - | - |
$307 5,569 kWh |
$70 12 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $521 Cost: $486 |
$380 | 6,741 | $141 | 24 | - | - | - | - | - | - |
$380 6,741 kWh |
$141 24 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $313 Cost: $200 |
$313 | 5,569 | - | - | - | - | - | - | - | - |
$313 5,569 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH |
Savings: $957 Cost: $103 |
$793 | 14,361 | $164 | 28 | - | - | - | - | - | - |
$793 14,361 kWh |
$164 28 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,109 Cost: $1,536 |
$724 | 13,189 | $385 | 65 | - | - | - | - | - | - |
$724 13,189 kWh |
$385 65 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $980 Cost: $500 |
- | - | - | - | $980 | 245 | - | - | - | - |
- - kWh |
- - kW-months/year |
$980 245 MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $388 Cost: $240 |
- | - | - | - | - | - | $388 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$388 - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $158 Cost: - |
- | - | - | - | - | - | - | - | $158 | 12,600 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$158 12,600 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $4,803 Cost: $4,012 |
$2,517 | 45,429 | $760 | 129 | $980 | 245 | $388 | - | $158 | 12,600 | $2,517 45,429 kWh |
$760 129 kW-months/year |
$980 245 MMBtu |
$388 - Tgal |
$158 12,600 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $690 Cost: $1,147 |
$620 | 11,138 | $70 | 12 | - | - | - | - | - | - | $620 11,138 kWh |
$70 12 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) |