Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Synthetic Fiber |
NAICS | n/a |
SIC | 2221 - Broadwoven Fabric Mills, Manmade |
Sales | $5,000,000-$10,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 260,074 |
Annual Production | 11,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $400,694 | 24,991,208 | kWh | $0.02 |
Electricity Demand | $541,850 | 39,735 | kW-months/year | $13.64 |
Electricity Fees | $14,869 | - | $ | - |
Natural Gas | $160,363 | 45,835 | MMBtu | $3.50 |
Fuel Oil #2 | $121,593 | 28,870 | MMBtu | $4.21 |
TOTAL ENERGY COSTS | $1,261,682 | |||
RECOMMENDED SAVINGS* | $125,793 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $81,151 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $32,105 Cost: $53,256 |
$14,755 | 922,333 | $17,350 | 1,272 | - | - | - | - | - | - |
$14,755 922,333 kWh |
$17,350 1,272 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $19,107 Cost: $1,495 |
- | - | - | - | $19,107 | 4,905 | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,107 4,905 MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $9,578 Cost: $6,300 |
- | - | - | - | $9,578 | 2,481 | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,578 2,481 MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $562 Cost: $2,705 |
$365 | 22,860 | $197 | 14 | - | - | - | - | - | - |
$365 22,860 kWh |
$197 14 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,299 Cost: $9,865 |
$4,262 | 266,413 | $5,037 | 369 | - | - | - | - | - | - |
$4,262 266,413 kWh |
$5,037 369 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $10,500 Cost: $4,095 |
- | - | - | - | - | - | $10,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$10,500 - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6122 INSTALL SOLID WASTE INCINERATOR FOR HEAT |
Savings: $44,642 Cost: $16,696 |
- | - | - | - | $38,342 | 9,946 | - | - | $6,300 | 109,500 |
- - kWh |
- - kW-months/year |
$38,342 9,946 MMBtu |
- - Tgal |
$6,300 109,500 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $125,793 Cost: $94,412 |
$19,382 | 1,211,606 | $22,584 | 1,655 | $67,027 | 17,332 | $10,500 | - | $6,300 | 109,500 | $19,382 1,211,606 kWh |
$22,584 1,655 kW-months/year |
$67,027 17,332 MMBtu |
$10,500 - Tgal |
$6,300 109,500 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $81,151 Cost: $77,716 |
$19,382 | 1,211,606 | $22,584 | 1,655 | $28,685 | 7,386 | $10,500 | - | - | - | $19,382 1,211,606 kWh |
$22,584 1,655 kW-months/year |
$28,685 7,386 MMBtu |
$10,500 - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) |