Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Glass Figurines |
NAICS | n/a |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 61,000 |
Annual Production | 700,000 Pieces |
Production Hrs. Annual | 2,808 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $62,982 | 1,103,165 | kWh | $0.06 |
Electricity Demand | $24,521 | 5,185 | kW-months/year | $4.73 |
Electricity Fees | $3,853 | - | $ | - |
Natural Gas | $13,442 | 1,936 | MMBtu | $6.94 |
LPG | $36,066 | 3,356 | MMBtu | $10.75 |
TOTAL ENERGY COSTS | $154,011 | |||
RECOMMENDED SAVINGS* | $76,874 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,177 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | LPG | Solid Waste (non-haz) | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,767 Cost: $8,940 |
$3,404 | 59,496 | $1,363 | 288 | - | - | - | - | - | - | - | - |
$3,404 59,496 kWh |
$1,363 288 kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $61,697 Cost: - |
- | - | - | - | $25,631 | 3,356 | $36,066 | 3,356 | - | - | - | - |
- - kWh |
- - kW-months/year |
$25,631 3,356 MMBtu |
$36,066 3,356 MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $218 Cost: $78 |
- | - | - | - | $218 | 54 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$218 54 MMBtu |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $4,965 Cost: $10,000 |
- | - | - | - | - | - | - | - | $4,965 | 60,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$4,965 60,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,227 Cost: $2,760 |
- | - | - | - | - | - | - | - | - | - | $5,227 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - lb |
$5,227 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,874 Cost: $21,778 |
$3,404 | 59,496 | $1,363 | 288 | $25,849 | 3,410 | $36,066 | 3,356 | $4,965 | 60,000 | $5,227 | - | $3,404 59,496 kWh |
$1,363 288 kW-months/year |
$25,849 3,410 MMBtu |
$36,066 3,356 MMBtu |
$4,965 60,000 lb |
$5,227 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,177 Cost: $21,778 |
$3,404 | 59,496 | $1,363 | 288 | $218 | 54 | - | - | $4,965 | 60,000 | $5,227 | - | $3,404 59,496 kWh |
$1,363 288 kW-months/year |
$218 54 MMBtu |
- - MMBtu |
$4,965 60,000 lb |
$5,227 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | LPG | Solid Waste (non-haz) | By-product Production |