Assessment Year 1982
Principal Product TEMPERED SAFETY GLASS
NAICS n/a
SIC 3231 - Products Of Purchased Glass
Sales $1,000,000-$5,000,000
# of Employees 40
Plant Area (Sq.Ft.) 0
Annual Production 875 Thousand Feet
Production Hrs. Annual 4,000
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $44,468 836,460 kWh $0.05
Natural Gas $17,885 6,246 MMBtu $2.86
TOTAL ENERGY COSTS $62,353
RECOMMENDED SAVINGS* $8,835 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4131 REPLACE OVER-SIZE MOTORS AND PUMPS WITH OPTIMUM SIZE Savings:
$7,801
Cost:
$6,550
$7,801 283,411 - - $7,801
283,411
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$458
Cost:
$99
$458 6,155 - - $458
6,155
kWh
-
-
MMBtu
03: 2.5122 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS Savings:
$348
Cost:
$432
$348 9,379 - - $348
9,379
kWh
-
-
MMBtu
04: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC Savings:
$228
Cost:
$140
$65 2,345 $163 54 $65
2,345
kWh
$163
54
MMBtu
TOTAL RECOMMENDED Savings:
$8,835
Cost:
$7,221
$8,672 301,290 $163 54 $8,672
301,290
kWh
$163
54
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas