Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1985
Principal Product INSTRUMENT PANELBOARDS
NAICS n/a
SIC 3613 - Switchgear And Switchboard Apparatus
Sales $5,000,000-$10,000,000
# of Employees 140
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 2,080
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,291 1,936,694 kWh $0.05
Natural Gas $6,641 1,755 MMBtu $3.78
TOTAL ENERGY COSTS $97,932
RECOMMENDED SAVINGS* $15,926 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,380
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$678
Cost:
$1,252
$678 12,016 - - $678
12,016
kWh
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$4,344
Cost:
$3,461
$6,612 140,680 $(-2,268) (-600) $6,612
140,680
kWh
$(-2,268)
(-600)
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$748
Cost:
$400
- - $748 198 -
-
kWh
$748
198
MMBtu
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$1,056
Cost:
$330
$1,056 - - - $1,056
-
kWh
-
-
MMBtu
05: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF Savings:
$1,954
Cost:
$4,000
$1,954 49,824 - - $1,954
49,824
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,146
Cost:
$35,020
$7,146 157,093 - - $7,146
157,093
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$15,926
Cost:
$44,463
$17,446 359,613 $(-1,520) (-402) $17,446
359,613
kWh
$(-1,520)
(-402)
MMBtu
TOTAL IMPLEMENTED Savings:
$3,380
Cost:
$5,652
$2,632 61,840 $748 198 $2,632
61,840
kWh
$748
198
MMBtu
Savings
Cost
$ kWh $ MMBtu