IAC logo
IAC Assessment: OK0265
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0265
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1988
Principal Product PROCESSED TUBING
NAICS n/a
SIC 3498 - Fabricated Pipe And Fittings
Sales $10,000,000-$50,000,000
# of Employees 167
Plant Area (Sq.Ft.) 0
Annual Production 75,000 Tons
Production Hrs. Annual 6,000
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $148,805 2,681,419 kWh $0.06
Natural Gas $179,814 87,550 MMBtu $2.05
TOTAL ENERGY COSTS $328,619
RECOMMENDED SAVINGS* $64,689 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $58,999
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$204
Cost:
$450
- - $204 59 - - -
-
kWh
$204
59
MMBtu
-
-
$
02: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$2,711
Cost:
-
$2,711 45,721 - - - - $2,711
45,721
kWh
-
-
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,364
Cost:
$901
$1,364 23,154 - - - - $1,364
23,154
kWh
-
-
MMBtu
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,423
Cost:
$15
$1,423 24,033 - - - - $1,423
24,033
kWh
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,790
Cost:
$4,590
$3,759 63,306 - - $31 - $3,759
63,306
kWh
-
-
MMBtu
$31
-
$
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$1,900
Cost:
$4,720
- - $1,900 860 - - -
-
kWh
$1,900
860
MMBtu
-
-
$
07: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$53,297
Cost:
-
$53,297 - - - - - $53,297
-
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$64,689
Cost:
$10,676
$62,554 156,214 $2,104 919 $31 - $62,554
156,214
kWh
$2,104
919
MMBtu
$31
-
$
TOTAL IMPLEMENTED Savings:
$58,999
Cost:
$1,366
$58,795 92,908 $204 59 - - $58,795
92,908
kWh
$204
59
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes