Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1989
Principal Product ARCHITECTURAL GLASS
NAICS n/a
SIC 3231 - Products Of Purchased Glass
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 5,000
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $238,083 8,909,144 kWh $0.03
Natural Gas $18,705 5,720 MMBtu $3.27
TOTAL ENERGY COSTS $256,788
RECOMMENDED SAVINGS* $63,106 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $58,547
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$48,600
Cost:
$7,500
$48,600 1,827,081 - - - - $48,600
1,827,081
kWh
-
-
MMBtu
-
-
$
02: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$4,666
Cost:
-
$4,666 93,494 - - - - $4,666
93,494
kWh
-
-
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$423
Cost:
$510
$423 8,499 - - - - $423
8,499
kWh
-
-
MMBtu
-
-
$
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$3,413
Cost:
-
- - $3,413 1,044 - - -
-
kWh
$3,413
1,044
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$319
Cost:
$504
$319 5,275 - - - - $319
5,275
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$217
Cost:
$465
$217 3,810 - - - - $217
3,810
kWh
-
-
MMBtu
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,445
Cost:
$629
$1,445 54,220 - - - - $1,445
54,220
kWh
-
-
MMBtu
-
-
$
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$393
Cost:
$1,086
$232 6,741 - - $161 - $232
6,741
kWh
-
-
MMBtu
$161
-
$
09: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$3,630
Cost:
$21,600
- - $3,630 1,110 - - -
-
kWh
$3,630
1,110
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$63,106
Cost:
$32,294
$55,902 1,999,120 $7,043 2,154 $161 - $55,902
1,999,120
kWh
$7,043
2,154
MMBtu
$161
-
$
TOTAL IMPLEMENTED Savings:
$58,547
Cost:
$8,639
$55,134 1,983,294 $3,413 1,044 - - $55,134
1,983,294
kWh
$3,413
1,044
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes