Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1989
Principal Product CUSTOM BUSINESS FORMS
NAICS n/a
SIC 2761 - Manifold Business Forms
Sales $10,000,000-$50,000,000
# of Employees 118
Plant Area (Sq.Ft.) 0
Annual Production 1,300,000 Pounds
Production Hrs. Annual 6,240
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $129,134 3,082,943 kWh $0.04
TOTAL ENERGY COSTS $129,134
RECOMMENDED SAVINGS* $34,431 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,383
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,071
Cost:
$616
$2,071 42,790 - - - - $2,071
42,790
kWh
-
-
MMBtu
-
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$6,240
Cost:
$15,500
$10,505 303,048 $(-4,265) (-1,292) - - $10,505
303,048
kWh
$(-4,265)
(-1,292)
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$505
Cost:
$622
$568 9,965 - - $(-63) - $568
9,965
kWh
-
-
MMBtu
$(-63)
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,924
Cost:
$1,809
$1,924 43,962 - - - - $1,924
43,962
kWh
-
-
MMBtu
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,638
Cost:
-
$2,638 60,668 - - - - $2,638
60,668
kWh
-
-
MMBtu
-
-
$
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$894
Cost:
$215
$894 25,791 - - - - $894
25,791
kWh
-
-
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$616
Cost:
-
$646 18,757 - - $(-30) - $646
18,757
kWh
-
-
MMBtu
$(-30)
-
$
08: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$9,879
Cost:
$15,700
$9,879 - - - - - $9,879
-
kWh
-
-
MMBtu
-
-
$
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$9,664
Cost:
$23,469
$9,664 278,722 - - - - $9,664
278,722
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$34,431
Cost:
$57,931
$38,789 783,703 $(-4,265) (-1,292) $(-93) - $38,789
783,703
kWh
$(-4,265)
(-1,292)
MMBtu
$(-93)
-
$
TOTAL IMPLEMENTED Savings:
$14,383
Cost:
$18,140
$18,678 495,016 $(-4,265) (-1,292) $(-30) - $18,678
495,016
kWh
$(-4,265)
(-1,292)
MMBtu
$(-30)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes