IAC logo
IAC Assessment: OK0308
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0308
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1990
Principal Product COMPUTER HARD DRIVE REP.
NAICS n/a
SIC 3572 - Computer Storage Devices
Sales $10,000,000-$50,000,000
# of Employees 400
Plant Area (Sq.Ft.) 0
Annual Production 60,000 Pieces
Production Hrs. Annual 4,420
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $390,200 8,193,142 kWh $0.05
Natural Gas $16,918 5,394 MMBtu $3.14
TOTAL ENERGY COSTS $407,118
RECOMMENDED SAVINGS* $64,891 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,727
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,691
Cost:
$160
$2,691 46,014 - - $2,691
46,014
kWh
-
-
MMBtu
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$157
Cost:
$228
$157 4,396 - - $157
4,396
kWh
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$407
Cost:
$132
$407 7,620 - - $407
7,620
kWh
-
-
MMBtu
04: 2.1222 INSTALL TURBULATORS Savings:
$214
Cost:
$260
- - $214 65 -
-
kWh
$214
65
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,258
Cost:
$2,275
$1,258 28,722 - - $1,258
28,722
kWh
-
-
MMBtu
06: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$52,043
Cost:
$42,000
$52,043 (-32,825) - - $52,043
(-32,825)
kWh
-
-
MMBtu
07: 2.2624 USE COLD WASTE WATER TO COOL CHILLER FEED WATER Savings:
$8,121
Cost:
$14,000
$8,121 230,070 - - $8,121
230,070
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$64,891
Cost:
$59,055
$64,677 283,997 $214 65 $64,677
283,997
kWh
$214
65
MMBtu
TOTAL IMPLEMENTED Savings:
$4,727
Cost:
$3,055
$4,513 86,752 $214 65 $4,513
86,752
kWh
$214
65
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas