Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1992
Principal Product CONFECTIONERY
NAICS n/a
SIC 2064 - Candy & Other Confectionery Products
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 30,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $288,863 5,270,223 kWh $0.05
Natural Gas $114,375 41,171 MMBtu $2.78
TOTAL ENERGY COSTS $403,238
RECOMMENDED SAVINGS* $26,674 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,286
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,816
Cost:
-
- - $5,816 2,092 - - -
-
kWh
$5,816
2,092
MMBtu
-
-
$
02: 2.2123 INSULATE FEEDWATER TANK Savings:
$253
Cost:
$150
- - $253 91 - - -
-
kWh
$253
91
MMBtu
-
-
$
03: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES Savings:
$267
Cost:
$69
- - $267 96 - - -
-
kWh
$267
96
MMBtu
-
-
$
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$220
Cost:
$185
- - $220 79 - - -
-
kWh
$220
79
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,767
Cost:
$2,434
$2,361 43,083 - - $(-594) - $2,361
43,083
kWh
-
-
MMBtu
$(-594)
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$730
Cost:
$138
$730 16,706 - - - - $730
16,706
kWh
-
-
MMBtu
-
-
$
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$17,621
Cost:
$23,222
$18,173 242,087 $(-1,235) (-540) $683 - $18,173
242,087
kWh
$(-1,235)
(-540)
MMBtu
$683
-
$
TOTAL RECOMMENDED Savings:
$26,674
Cost:
$26,198
$21,264 301,876 $5,321 1,818 $89 - $21,264
301,876
kWh
$5,321
1,818
MMBtu
$89
-
$
TOTAL IMPLEMENTED Savings:
$7,286
Cost:
$542
$730 16,706 $6,556 2,358 - - $730
16,706
kWh
$6,556
2,358
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes