Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1995
Principal Product Magazines, Commercial printing
NAICS n/a
SIC 2759 - Commercial Printing, Nec
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 330,000
Annual Production 457,000,000 Pieces
Production Hrs. Annual 8,400
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,094,579 25,478,312 kWh $0.04
Natural Gas $419,662 114,998 MMBtu $3.65
TOTAL ENERGY COSTS $1,514,241
RECOMMENDED SAVINGS* $128,363 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $112,074
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Other Liquid (haz) Electricity Usage Natural Gas Water Disposal Other Liquid (haz)
$ kWh $ MMBtu $ Tgal $ gal
01: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$63,653
Cost:
$25,000
$63,653 1,473,916 - - - - - - $63,653
1,473,916
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$28,374
Cost:
$48,000
$38,799 733,587 $(-10,425) (-3,337) - - - - $38,799
733,587
kWh
$(-10,425)
(-3,337)
MMBtu
-
-
Tgal
-
-
gal
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$5,482
Cost:
$2,520
$5,482 126,905 - - - - - - $5,482
126,905
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$3,490
Cost:
$2,500
$3,490 80,891 - - - - - - $3,490
80,891
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$2,792
Cost:
$160
$2,792 53,634 - - - - - - $2,792
53,634
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,382
Cost:
$1,650
$2,382 55,100 - - - - - - $2,382
55,100
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$2,143
Cost:
$1,000
$2,143 49,531 - - - - - - $2,143
49,531
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
08: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$1,578
Cost:
$1,000
$1,578 - - - - - - - $1,578
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
09: 3.8136 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED Savings:
$8,089
Cost:
$4,295
- - - - - - $8,089 4,213 -
-
kWh
-
-
MMBtu
-
-
Tgal
$8,089
4,213
gal
10: 3.4131 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT Savings:
$6,080
Cost:
$500
- - - - $6,080 - - - -
-
kWh
-
-
MMBtu
$6,080
-
Tgal
-
-
gal
11: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$4,300
Cost:
-
- - - - $4,300 - - - -
-
kWh
-
-
MMBtu
$4,300
-
Tgal
-
-
gal
TOTAL RECOMMENDED Savings:
$128,363
Cost:
$86,625
$120,319 2,573,564 $(-10,425) (-3,337) $10,380 - $8,089 4,213 $120,319
2,573,564
kWh
$(-10,425)
(-3,337)
MMBtu
$10,380
-
Tgal
$8,089
4,213
gal
TOTAL IMPLEMENTED Savings:
$112,074
Cost:
$78,795
$104,030 2,207,503 $(-10,425) (-3,337) $10,380 - $8,089 4,213 $104,030
2,207,503
kWh
$(-10,425)
(-3,337)
MMBtu
$10,380
-
Tgal
$8,089
4,213
gal
Savings
Cost
$ kWh $ MMBtu $ Tgal $ gal
Electricity Usage Natural Gas Water Disposal Other Liquid (haz) Electricity Usage Natural Gas Water Disposal Other Liquid (haz)