Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1998
Principal Product Trailers
NAICS n/a
SIC 3715 - Truck Trailers
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 50,000
Annual Production 3,200 Pieces
Production Hrs. Annual 2,080
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $29,361 613,130 kWh $0.05
Electricity Demand $12,597 - kW-months/year -
Natural Gas $9,840 2,946 MMBtu $3.34
TOTAL ENERGY COSTS $39,718
RECOMMENDED SAVINGS* $80,529 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $38,929
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost
$ kWh $ kW-months/year $ lb $ $
01: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$956
Cost:
$2,140
$956 35,170 - - - - - - $956
35,170
kWh
-
-
kW-months/year
-
-
lb
-
-
$
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$15,633
Cost:
-
$8,110 169,402 $7,523 - - - - - $8,110
169,402
kWh
$7,523
-
kW-months/year
-
-
lb
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$715
Cost:
$250
$715 26,377 - - - - - - $715
26,377
kWh
-
-
kW-months/year
-
-
lb
-
-
$
04: 2.8123 PAY UTILITY BILLS ON TIME Savings:
$656
Cost:
-
$656 13,775 - - - - - - $656
13,775
kWh
-
-
kW-months/year
-
-
lb
-
-
$
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$20,969
Cost:
$50,000
- - - - $20,969 - - - -
-
kWh
-
-
kW-months/year
$20,969
-
lb
-
-
$
06: 4.5130 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS Savings:
$41,600
Cost:
$260,000
- - - - - - $41,600 - -
-
kWh
-
-
kW-months/year
-
-
lb
$41,600
-
$
TOTAL RECOMMENDED Savings:
$80,529
Cost:
$312,390
$10,437 244,724 $7,523 - $20,969 - $41,600 - $10,437
244,724
kWh
$7,523
-
kW-months/year
$20,969
-
lb
$41,600
-
$
TOTAL IMPLEMENTED Savings:
$38,929
Cost:
$52,390
$10,437 244,724 $7,523 - $20,969 - - - $10,437
244,724
kWh
$7,523
-
kW-months/year
$20,969
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost