Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1998 |
Principal Product | Wellhead equipment, gate valves |
NAICS | n/a |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | $50,000,000-$100,000,000 |
# of Employees | 144 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 4,680 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $106,839 | 3,741,208 | kWh | $0.03 |
Electricity Demand | $78,787 | 8,570 | kW-months/year | $9.19 |
Electricity Fees | $6,300 | - | $ | - |
Natural Gas | $46,450 | 11,062 | MMBtu | $4.20 |
TOTAL ENERGY COSTS | $270,409 | |||
RECOMMENDED SAVINGS* | $133,884 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $93,103 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $329 Cost: $1,158 |
$228 | 7,913 | $101 | 11 | - | - | - | - | - | - |
$228 7,913 kWh |
$101 11 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,641 Cost: $12,354 |
$1,446 | 50,410 | $1,195 | 130 | - | - | - | - | - | - |
$1,446 50,410 kWh |
$1,195 130 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $84,000 Cost: $330,000 |
- | - | - | - | - | - | $84,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$84,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $6,750 Cost: $59,000 |
- | - | - | - | - | - | - | - | $6,750 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$6,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $23,508 Cost: $27,000 |
- | - | $23,508 | 3,000 | - | - | - | - | - | - |
- - kWh |
$23,508 3,000 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,039 Cost: $7,452 |
$2,039 | 112,837 | - | - | - | - | - | - | - | - |
$2,039 112,837 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $7,882 Cost: - |
- | - | - | - | $7,882 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,882 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $6,735 Cost: - |
- | - | - | - | $6,735 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,735 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,884 Cost: $436,964 |
$3,713 | 171,160 | $24,804 | 3,141 | $14,617 | - | $84,000 | - | $6,750 | - | $3,713 171,160 kWh |
$24,804 3,141 kW-months/year |
$14,617 - lb |
$84,000 - $ |
$6,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $93,103 Cost: $338,610 |
$2,267 | 120,750 | $101 | 11 | $6,735 | - | $84,000 | - | - | - | $2,267 120,750 kWh |
$101 11 kW-months/year |
$6,735 - lb |
$84,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost |