Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2003 |
Principal Product | Poultry Processing and Packaging |
NAICS | 311615 - Poultry Processing |
SIC | 2015 - Poultry Slaughtering And Processing |
Sales | $100,000,000-$500,000,000 |
# of Employees | 920 |
Plant Area (Sq.Ft.) | 101,380 |
Annual Production | 70,000,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $542,790 | 25,683,698 | kWh | $0.02 |
Electricity Demand | $230,967 | 57,024 | kW-months/year | $4.05 |
Electricity Fees | $540,844 | - | $ | - |
Natural Gas | $591,285 | 141,750 | MMBtu | $4.17 |
TOTAL ENERGY COSTS | $2,410,568 | |||
RECOMMENDED SAVINGS* | $89,431 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,643 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,773 Cost: $8,717 |
- | - | - | - | $3,773 | 941 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,773 941 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $6,638 Cost: $7,445 |
- | - | - | - | $6,638 | 1,656 | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,638 1,656 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $279 Cost: $300 |
- | - | - | - | $279 | 70 | - | - | - | - |
- - kWh |
- - kW-months/year |
$279 70 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,891 Cost: $450 |
- | - | - | - | $3,891 | 971 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,891 971 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $930 Cost: $1,017 |
$930 | 43,472 | - | - | - | - | - | - | - | - |
$930 43,472 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $996 Cost: $4,003 |
$505 | 23,582 | $206 | 57 | - | - | $285 | - | - | - |
$505 23,582 kWh |
$206 57 kW-months/year |
- - MMBtu |
$285 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $28,433 Cost: $113,760 |
$28,433 | 1,328,849 | - | - | - | - | - | - | - | - |
$28,433 1,328,849 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $20,839 Cost: $1,606 |
- | - | $20,839 | 5,145 | - | - | - | - | - | - |
- - kWh |
$20,839 5,145 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $23,652 Cost: $4,495 |
- | - | - | - | - | - | - | - | $23,652 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$23,652 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $89,431 Cost: $141,793 |
$29,868 | 1,395,903 | $21,045 | 5,202 | $14,581 | 3,638 | $285 | - | $23,652 | - | $29,868 1,395,903 kWh |
$21,045 5,202 kW-months/year |
$14,581 3,638 MMBtu |
$285 - $ |
$23,652 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,643 Cost: $13,804 |
$505 | 23,582 | $21,045 | 5,202 | $10,808 | 2,697 | $285 | - | - | - | $505 23,582 kWh |
$21,045 5,202 kW-months/year |
$10,808 2,697 MMBtu |
$285 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Water Consumption |