Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2004 |
Principal Product | Custom Made Wood Furniture |
NAICS | 337215 - Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2541 - Wood Partitions And Fixtures |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 7,800 Pieces |
Production Hrs. Annual | 2,912 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $41,287 | 1,523,495 | kWh | $0.03 |
Electricity Demand | $47,317 | 5,906 | kW-months/year | $8.01 |
Electricity Fees | $21,337 | - | $ | - |
Natural Gas | $51,966 | 5,552 | MMBtu | $9.36 |
TOTAL ENERGY COSTS | $197,021 | |||
RECOMMENDED SAVINGS* | $50,501 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $42,849 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $19,051 Cost: $4,180 |
- | - | - | - | $19,051 | 2,100 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,051 2,100 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING |
Savings: $19,260 Cost: $5,950 |
- | - | - | - | $19,260 | 2,123 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,260 2,123 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $6,344 Cost: $2,100 |
- | - | $6,344 | 680 | - | - | - | - | - | - | - | - |
- - kWh |
$6,344 680 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,308 Cost: $600 |
$280 | 10,337 | $81 | 14 | - | - | $600 | - | - | - | $347 | - |
$280 10,337 kWh |
$81 14 kW-months/year |
- - MMBtu |
$600 - $ |
- - $ |
$347 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,876 Cost: $559 |
$1,109 | 40,926 | $959 | 166 | - | - | $(-192) | - | - | - | - | - |
$1,109 40,926 kWh |
$959 166 kW-months/year |
- - MMBtu |
$(-192) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $1,545 Cost: - |
- | - | - | - | - | - | - | - | $1,545 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,545 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $700 Cost: - |
- | - | - | - | - | - | $700 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$700 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $417 Cost: $707 |
$417 | 15,375 | - | - | - | - | - | - | - | - | - | - |
$417 15,375 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,501 Cost: $14,096 |
$1,806 | 66,638 | $7,384 | 860 | $38,311 | 4,223 | $1,108 | - | $1,545 | - | $347 | - | $1,806 66,638 kWh |
$7,384 860 kW-months/year |
$38,311 4,223 MMBtu |
$1,108 - $ |
$1,545 - $ |
$347 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $42,849 Cost: $11,396 |
$1,526 | 56,301 | $959 | 166 | $38,311 | 4,223 | $508 | - | $1,545 | - | - | - | $1,526 56,301 kWh |
$959 166 kW-months/year |
$38,311 4,223 MMBtu |
$508 - $ |
$1,545 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |