Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2012 |
Principal Product | Hardwood Flooring |
NAICS | 321918 - Other Millwork (including Flooring) |
SIC | 2426 - Hardwood Dimension & Flooring Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 1,500 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,047,458 | 21,619,560 | kWh | $0.05 |
Electricity Demand | $383,093 | 47,129 | kW-months/year | $8.13 |
Natural Gas | $22,567 | 2,902 | MMBtu | $7.78 |
TOTAL ENERGY COSTS | $1,453,118 | |||
RECOMMENDED SAVINGS* | $320,900 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $47,500 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Wood | Electricity Usage | Electricity Demand | Natural Gas | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,500 Cost: $1,700 |
$1,220 | 25,100 | $280 | 34 | - | - | - | - |
$1,220 25,100 kWh |
$280 34 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,200 Cost: $27,500 |
$8,500 | 175,500 | $2,700 | 336 | - | - | - | - |
$8,500 175,500 kWh |
$2,700 336 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,400 Cost: $10,000 |
$1,800 | 36,900 | $600 | 72 | - | - | - | - |
$1,800 36,900 kWh |
$600 72 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $28,900 Cost: $15,100 |
$15,900 | 332,000 | $13,000 | 1,600 | - | - | - | - |
$15,900 332,000 kWh |
$13,000 1,600 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $9,000 Cost: $500 |
- | - | - | - | - | - | $9,000 | 10,600 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$9,000 10,600 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $7,200 Cost: $1,000 |
$(-9,800) | (-202,000) | $(-5,300) | (-648) | $22,300 | 2,900 | - | - |
$(-9,800) (-202,000) kWh |
$(-5,300) (-648) kW-months/year |
$22,300 2,900 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $248,000 Cost: $675,000 |
$248,000 | 4,400,000 | - | - | - | - | - | - |
$248,000 4,400,000 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $12,700 Cost: $13,000 |
$12,700 | 187,500 | - | - | - | - | - | - |
$12,700 187,500 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $320,900 Cost: $743,800 |
$278,320 | 4,955,000 | $11,280 | 1,394 | $22,300 | 2,900 | $9,000 | 10,600 | $278,320 4,955,000 kWh |
$11,280 1,394 kW-months/year |
$22,300 2,900 MMBtu |
$9,000 10,600 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $47,500 Cost: $26,600 |
$7,900 | 166,900 | $8,300 | 1,024 | $22,300 | 2,900 | $9,000 | 10,600 | $7,900 166,900 kWh |
$8,300 1,024 kW-months/year |
$22,300 2,900 MMBtu |
$9,000 10,600 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Wood | Electricity Usage | Electricity Demand | Natural Gas | Wood |