IAC logo
IAC Assessment: OK0862
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0862
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2013
Principal Product Air Filtration Systems
NAICS 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
SIC 3564 - Blowers And Fans
Sales $50,000,000-$100,000,000
# of Employees 125
Plant Area (Sq.Ft.) 280,000
Annual Production 4,200 Units
Production Hrs. Annual 4,500
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $231,508 5,287,563 kWh $0.04
Electricity Demand $58,406 13,125 kW-months/year $4.45
Natural Gas $131,279 20,508 MMBtu $6.40
TOTAL ENERGY COSTS $430,081
RECOMMENDED SAVINGS* $44,281 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,733
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$2,733
Cost:
-
- - - - $2,733 - -
-
kWh
-
-
kW-months/year
$2,733
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$14,745
Cost:
$52,650
$11,600 264,870 $3,145 707 - - $11,600
264,870
kWh
$3,145
707
kW-months/year
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,000
Cost:
$2,520
$3,000 68,580 - - - - $3,000
68,580
kWh
-
-
kW-months/year
-
-
$
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$600
Cost:
-
- - $600 138 - - -
-
kWh
$600
138
kW-months/year
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,426
Cost:
$53,400
$10,565 241,200 $2,861 643 - - $10,565
241,200
kWh
$2,861
643
kW-months/year
-
-
$
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$2,177
Cost:
$8,000
$1,790 40,874 $387 87 - - $1,790
40,874
kWh
$387
87
kW-months/year
-
-
$
07: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$7,599
Cost:
$12,000
$6,095 139,163 $1,504 338 - - $6,095
139,163
kWh
$1,504
338
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$44,281
Cost:
$128,570
$33,050 754,687 $8,498 1,913 $2,733 - $33,050
754,687
kWh
$8,498
1,913
kW-months/year
$2,733
-
$
TOTAL IMPLEMENTED Savings:
$5,733
Cost:
$2,520
$3,000 68,580 - - $2,733 - $3,000
68,580
kWh
-
-
kW-months/year
$2,733
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes