Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1988
Principal Product FROZEN FRENCH FRIES
NAICS n/a
SIC 2038 - Frozen Specialties, Nec
Sales $5,000,000-$10,000,000
# of Employees 86
Plant Area (Sq.Ft.) 0
Annual Production 35,000,000 Pounds
Production Hrs. Annual 8,064
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $186,968 4,135,111 kWh $0.05
LPG $186,231 43,968 MMBtu $4.24
TOTAL ENERGY COSTS $373,199
RECOMMENDED SAVINGS* $38,619 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,379
#|Description Savings
Cost
Status Electricity Usage LPG Administrative Changes Electricity Usage LPG Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$3,046
Cost:
-
$3,046 67,702 - - - - $3,046
67,702
kWh
-
-
MMBtu
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,878
Cost:
$858
- - $2,878 694 - - -
-
kWh
$2,878
694
MMBtu
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,704
Cost:
$1,375
- - $2,704 651 - - -
-
kWh
$2,704
651
MMBtu
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,853
Cost:
$1,546
- - $1,853 446 - - -
-
kWh
$1,853
446
MMBtu
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$125
Cost:
$114
$125 2,638 - - - - $125
2,638
kWh
-
-
MMBtu
-
-
$
06: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$5,439
Cost:
$4,800
$5,439 120,750 - - - - $5,439
120,750
kWh
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$696
Cost:
$845
$340 7,620 - - $356 - $340
7,620
kWh
-
-
MMBtu
$356
-
$
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$891
Cost:
$1,213
- - $891 215 - - -
-
kWh
$891
215
MMBtu
-
-
$
09: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS Savings:
$19,381
Cost:
$29,735
- - $19,381 4,670 - - -
-
kWh
$19,381
4,670
MMBtu
-
-
$
10: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$1,606
Cost:
$3,600
$1,606 - - - - - $1,606
-
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$38,619
Cost:
$44,086
$10,556 198,710 $27,707 6,676 $356 - $10,556
198,710
kWh
$27,707
6,676
MMBtu
$356
-
$
TOTAL IMPLEMENTED Savings:
$12,379
Cost:
$6,985
$8,610 191,090 $3,769 909 - - $8,610
191,090
kWh
$3,769
909
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage LPG Administrative Changes Electricity Usage LPG Administrative Changes