Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1989
Principal Product WOOLEN TEXTILES
NAICS n/a
SIC 2231 - Broadwoven Fabric Mills, Wool
Sales $50,000,000-$100,000,000
# of Employees 320
Plant Area (Sq.Ft.) 0
Annual Production 51,840 Thousand Feet
Production Hrs. Annual 5,760
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $348,138 12,344,080 kWh $0.03
Natural Gas $587,111 151,304 MMBtu $3.88
TOTAL ENERGY COSTS $935,249
RECOMMENDED SAVINGS* $40,591 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,808
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE Savings:
$7,313
Cost:
-
- - $7,313 1,909 - - -
-
kWh
$7,313
1,909
MMBtu
-
-
$
02: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$2,279
Cost:
$385
$1,531 80,598 - - $748 - $1,531
80,598
kWh
-
-
MMBtu
$748
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$18,329
Cost:
$5,500
- - $18,329 4,786 - - -
-
kWh
$18,329
4,786
MMBtu
-
-
$
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED Savings:
$4,079
Cost:
$4,000
- - $3,960 1,034 $119 - -
-
kWh
$3,960
1,034
MMBtu
$119
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,207
Cost:
$1,800
$1,207 43,083 - - - - $1,207
43,083
kWh
-
-
MMBtu
-
-
$
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,243
Cost:
$1,755
$1,243 43,962 - - - - $1,243
43,962
kWh
-
-
MMBtu
-
-
$
07: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$6,141
Cost:
$14,400
$6,141 219,226 - - - - $6,141
219,226
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$40,591
Cost:
$27,840
$10,122 386,869 $29,602 7,729 $867 - $10,122
386,869
kWh
$29,602
7,729
MMBtu
$867
-
$
TOTAL IMPLEMENTED Savings:
$8,808
Cost:
$7,940
$3,981 167,643 $3,960 1,034 $867 - $3,981
167,643
kWh
$3,960
1,034
MMBtu
$867
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes