IAC logo
IAC Assessment: OR0075
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OR0075
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1989
Principal Product BUSINESS FORMS
NAICS n/a
SIC 2761 - Manifold Business Forms
Sales $5,000,000-$10,000,000
# of Employees 87
Plant Area (Sq.Ft.) 0
Annual Production 251 Tons
Production Hrs. Annual 6,000
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $40,677 941,970 kWh $0.04
Fuel Oil #6 $3,226 623 MMBtu $5.18
TOTAL ENERGY COSTS $43,903
RECOMMENDED SAVINGS* $3,136 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,064
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #6 Administrative Changes Electricity Usage Fuel Oil #6 Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$794
Cost:
$500
$794 18,464 - - - - $794
18,464
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$147
Cost:
$117
$121 2,931 - - $26 - $121
2,931
kWh
-
-
MMBtu
$26
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$228
Cost:
$213
$254 5,862 - - $(-26) - $254
5,862
kWh
-
-
MMBtu
$(-26)
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$78
Cost:
$94
$78 1,758 - - - - $78
1,758
kWh
-
-
MMBtu
-
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$925
Cost:
$1,340
- - $925 178 - - -
-
kWh
$925
178
MMBtu
-
-
$
06: 2.2532 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD Savings:
$833
Cost:
$1,175
$365 10,844 $468 90 - - $365
10,844
kWh
$468
90
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$131
Cost:
$244
$153 3,517 - - $(-22) - $153
3,517
kWh
-
-
MMBtu
$(-22)
-
$
TOTAL RECOMMENDED Savings:
$3,136
Cost:
$3,683
$1,765 43,376 $1,393 268 $(-22) - $1,765
43,376
kWh
$1,393
268
MMBtu
$(-22)
-
$
TOTAL IMPLEMENTED Savings:
$2,064
Cost:
$2,226
$1,644 40,445 $468 90 $(-48) - $1,644
40,445
kWh
$468
90
MMBtu
$(-48)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Fuel Oil #6 Administrative Changes Electricity Usage Fuel Oil #6 Administrative Changes