IAC logo
IAC Assessment: OR0183
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OR0183
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1993
Principal Product TV, VCR Assembly
NAICS n/a
SIC 3651 - Household Audio And Video Equipment
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 135,000
Annual Production 500,000 Pieces
Production Hrs. Annual 8,400
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $248,912 5,541,911 kWh $0.04
Natural Gas $38,341 9,030 MMBtu $4.25
TOTAL ENERGY COSTS $287,253
RECOMMENDED SAVINGS* $15,274 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,890
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Electricity Usage Personnel Changes
$ kWh $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$473
Cost:
$430
$531 15,826 $(-58) - $531
15,826
kWh
$(-58)
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,413
Cost:
$1,500
$1,413 54,513 - - $1,413
54,513
kWh
-
-
$
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$9,973
Cost:
$13,875
$9,973 - - - $9,973
-
kWh
-
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$444
Cost:
$740
$444 16,413 - - $444
16,413
kWh
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$159
Cost:
-
$159 4,103 - - $159
4,103
kWh
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,812
Cost:
$2,841
$2,812 128,957 - - $2,812
128,957
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$15,274
Cost:
$19,386
$15,332 219,812 $(-58) - $15,332
219,812
kWh
$(-58)
-
$
TOTAL IMPLEMENTED Savings:
$10,890
Cost:
$15,045
$10,948 32,239 $(-58) - $10,948
32,239
kWh
$(-58)
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Personnel Changes Electricity Usage Personnel Changes