Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1996
Principal Product printed bags
NAICS n/a
SIC 2671 - Paper Coated & Laminated, Packaging
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 45,000
Annual Production 13,600,000 Pieces
Production Hrs. Annual 2,250
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $14,289 265,240 kWh $0.05
Electricity Demand $351 1,296 kW-months/year $0.27
Electricity Fees $698 - $ -
Natural Gas $14,959 2,935 MMBtu $5.10
TOTAL ENERGY COSTS $45,245
RECOMMENDED SAVINGS* $3,894 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,354
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ lb $ $ $ $
01: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$1,953
Cost:
-
- - - - - - $1,953 129,100 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,953
129,100
lb
-
-
$
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$217
Cost:
$500
$149 4,396 $68 25 - - - - - - - - $149
4,396
kWh
$68
25
kW-months/year
-
-
$
-
-
lb
-
-
$
-
-
$
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$216
Cost:
$600
- - - - $216 - - - - - - - -
-
kWh
-
-
kW-months/year
$216
-
$
-
-
lb
-
-
$
-
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$324
Cost:
$1,589
$232 7,034 $92 35 - - - - - - - - $232
7,034
kWh
$92
35
kW-months/year
-
-
$
-
-
lb
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,184
Cost:
$6,354
$654 19,637 $267 101 - - - - $67 - $196 - $654
19,637
kWh
$267
101
kW-months/year
-
-
$
-
-
lb
$67
-
$
$196
-
$
TOTAL RECOMMENDED Savings:
$3,894
Cost:
$9,043
$1,035 31,067 $427 161 $216 - $1,953 129,100 $67 - $196 - $1,035
31,067
kWh
$427
161
kW-months/year
$216
-
$
$1,953
129,100
lb
$67
-
$
$196
-
$
TOTAL IMPLEMENTED Savings:
$3,354
Cost:
$6,854
$803 24,033 $335 126 - - $1,953 129,100 $67 - $196 - $803
24,033
kWh
$335
126
kW-months/year
-
-
$
$1,953
129,100
lb
$67
-
$
$196
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ lb $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Solid Waste (non-haz) Personnel Changes Ancillary Material Cost