Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 1997
Principal Product Corrugated Boxes
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 105
Plant Area (Sq.Ft.) 200,000
Annual Production 865,000,000 Thousand Feet
Production Hrs. Annual 6,000
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $143,265 4,128,664 kWh $0.03
Electricity Demand $40,182 9,216 kW-months/year $4.36
Electricity Fees $2,049 - $ -
Natural Gas $72,946 11,060 MMBtu $6.60
LPG $22,043 2,896 MMBtu $7.61
TOTAL ENERGY COSTS $302,922
RECOMMENDED SAVINGS* $44,511 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,817
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas LPG Water Disposal Electricity Usage Electricity Demand Electricity Fees Natural Gas LPG Water Disposal
$ kWh $ kW-months/year $ $ $ MMBtu $ MMBtu $ Tgal
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,780
Cost:
$500
- - - - - - $1,780 1,350 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,780
1,350
MMBtu
-
-
MMBtu
-
-
Tgal
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,037
Cost:
$9,611
$5,834 177,902 $1,203 276 - - - - - - - - $5,834
177,902
kWh
$1,203
276
kW-months/year
-
-
$
-
-
MMBtu
-
-
MMBtu
-
-
Tgal
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,504
Cost:
$7,050
$2,080 63,306 $424 97 - - - - - - - - $2,080
63,306
kWh
$424
97
kW-months/year
-
-
$
-
-
MMBtu
-
-
MMBtu
-
-
Tgal
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$3,760
Cost:
$18,000
- - - - - - $3,760 1,450 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$3,760
1,450
MMBtu
-
-
MMBtu
-
-
Tgal
05: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER Savings:
$17,480
Cost:
$2,870
$(-410) (-12,603) $(-110) (-25) - - - - - - $18,000 3,890,000 $(-410)
(-12,603)
kWh
$(-110)
(-25)
kW-months/year
-
-
$
-
-
MMBtu
-
-
MMBtu
$18,000
3,890,000
Tgal
06: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS Savings:
$10,600
Cost:
$81,640
$(-2,500) (-76,788) $(-700) (-154) - - $(-8,200) (-2,896) $22,000 2,896 - - $(-2,500)
(-76,788)
kWh
$(-700)
(-154)
kW-months/year
-
-
$
$(-8,200)
(-2,896)
MMBtu
$22,000
2,896
MMBtu
-
-
Tgal
07: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$1,350
Cost:
$3,375
- - - - $1,350 - - - - - - - -
-
kWh
-
-
kW-months/year
$1,350
-
$
-
-
MMBtu
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$44,511
Cost:
$123,046
$5,004 151,817 $817 194 $1,350 - $(-2,660) (-96) $22,000 2,896 $18,000 3,890,000 $5,004
151,817
kWh
$817
194
kW-months/year
$1,350
-
$
$(-2,660)
(-96)
MMBtu
$22,000
2,896
MMBtu
$18,000
3,890,000
Tgal
TOTAL IMPLEMENTED Savings:
$8,817
Cost:
$10,111
$5,834 177,902 $1,203 276 - - $1,780 1,350 - - - - $5,834
177,902
kWh
$1,203
276
kW-months/year
-
-
$
$1,780
1,350
MMBtu
-
-
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ MMBtu $ Tgal
Electricity Usage Electricity Demand Electricity Fees Natural Gas LPG Water Disposal Electricity Usage Electricity Demand Electricity Fees Natural Gas LPG Water Disposal