Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2000 |
Principal Product | Wood Pellets |
NAICS | n/a |
SIC | 2499 - Wood Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 0 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 57,000 Tons |
Production Hrs. Annual | 6,552 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $334,230 | 7,165,544 | kWh | $0.05 |
Electricity Demand | $647 | 176,244 | kW-months/year | $0.00 |
Electricity Fees | $336 | - | $ | - |
Natural Gas | $153,600 | 188,760 | MMBtu | $0.81 |
TOTAL ENERGY COSTS | $491,498 | |||
RECOMMENDED SAVINGS* | $161,043 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,481 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $152,880 Cost: $600,000 |
- | - | - | - | $153,600 | 33,580 | $(-720) | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$153,600 33,580 MMBtu |
$(-720) - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,537 Cost: $1,000 |
$1,973 | 48,651 | - | - | - | - | - | - | $564 | - | - | - |
$1,973 48,651 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$564 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,481 Cost: $18,298 |
$4,834 | 119,285 | $647 | 233 | - | - | - | - | - | - | - | - |
$4,834 119,285 kWh |
$647 233 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $145 Cost: $500 |
$(-80) | (-6) | - | - | - | - | - | - | - | - | $225 | - |
$(-80) (-6) kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$225 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $161,043 Cost: $619,798 |
$6,727 | 167,930 | $647 | 233 | $153,600 | 33,580 | $(-720) | - | $564 | - | $225 | - | $6,727 167,930 kWh |
$647 233 kW-months/year |
$153,600 33,580 MMBtu |
$(-720) - $ |
$564 - $ |
$225 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,481 Cost: $18,298 |
$4,834 | 119,285 | $647 | 233 | - | - | - | - | - | - | - | - | $4,834 119,285 kWh |
$647 233 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Water Consumption |