Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2002 |
Principal Product | 2 |
NAICS | n/a |
SIC | 1041 - Gold Ores |
Sales | $100,000,000-$500,000,000 |
# of Employees | 1,462 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 0 Pounds |
Production Hrs. Annual | 8,565 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $17,414,720 | 353,469,361 | kWh | $0.05 |
Electricity Demand | $216,146 | 518,750 | kW-months/year | $0.42 |
Electricity Fees | $6,000 | - | $ | - |
Natural Gas | $2,151,480 | 778,171 | MMBtu | $2.76 |
LPG | $3,377,411 | 594,294 | MMBtu | $5.68 |
TOTAL ENERGY COSTS | $23,165,757 | |||
RECOMMENDED SAVINGS* | $1,957,209 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $103,131 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1117 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION |
Savings: $577,590 Cost: $207,147 |
- | - | - | - | $577,590 | 154,024 |
- - kWh |
- - kW-months/year |
$577,590 154,024 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $958,574 Cost: $1,727,000 |
$819,644 | 16,234,542 | $138,930 | 27,792 | - | - |
$819,644 16,234,542 kWh |
$138,930 27,792 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $158,150 Cost: $118,500 |
- | - | - | - | $158,150 | 42,175 |
- - kWh |
- - kW-months/year |
$158,150 42,175 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $119,700 Cost: $241,870 |
$104,000 | 2,105,788 | $15,700 | 3,144 | - | - |
$104,000 2,105,788 kWh |
$15,700 3,144 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $69,350 Cost: $46,000 |
$60,810 | 1,246,590 | $8,540 | 1,708 | - | - |
$60,810 1,246,590 kWh |
$8,540 1,708 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $25,349 Cost: - |
$22,029 | 446,197 | $3,320 | 664 | - | - |
$22,029 446,197 kWh |
$3,320 664 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $20,311 Cost: $1,000 |
- | - | - | - | $20,311 | 5,582 |
- - kWh |
- - kW-months/year |
$20,311 5,582 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,470 Cost: $12,200 |
$12,190 | 260,250 | $1,280 | 256 | - | - |
$12,190 260,250 kWh |
$1,280 256 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $14,715 Cost: $45,000 |
- | - | - | - | $14,715 | 3,924 |
- - kWh |
- - kW-months/year |
$14,715 3,924 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,957,209 Cost: $2,398,717 |
$1,018,673 | 20,293,367 | $167,770 | 33,564 | $770,766 | 205,705 | $1,018,673 20,293,367 kWh |
$167,770 33,564 kW-months/year |
$770,766 205,705 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $103,131 Cost: $59,200 |
$73,000 | 1,506,840 | $9,820 | 1,964 | $20,311 | 5,582 | $73,000 1,506,840 kWh |
$9,820 1,964 kW-months/year |
$20,311 5,582 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |