Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2003 |
Principal Product | green dimensional lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 17,524,500 Units |
Production Hrs. Annual | 1,960 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $62,202 | 1,481,000 | kWh | $0.04 |
Electricity Demand | $54,965 | 10,410 | kW-months/year | $5.28 |
Electricity Fees | $5,136 | - | $ | - |
TOTAL ENERGY COSTS | $122,303 | |||
RECOMMENDED SAVINGS* | $220,245 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $132,250 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $117,000 Cost: $150,300 |
- | - | - | - | $117,000 | - | - | - |
- - kWh |
- - kW-months/year |
$117,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $78,000 Cost: $62,900 |
- | - | - | - | - | - | $78,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$78,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $9,500 Cost: - |
- | - | $9,500 | 1,788 | - | - | - | - |
- - kWh |
$9,500 1,788 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,080 Cost: $3,000 |
$2,160 | 51,600 | $920 | 176 | - | - | - | - |
$2,160 51,600 kWh |
$920 176 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,780 Cost: $15,000 |
$4,670 | 111,160 | $3,110 | 589 | - | - | - | - |
$4,670 111,160 kWh |
$3,110 589 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,390 Cost: $10,800 |
$2,330 | 55,300 | $2,060 | 390 | - | - | - | - |
$2,330 55,300 kWh |
$2,060 390 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $495 Cost: - |
$265 | 2,380 | $230 | 44 | - | - | - | - |
$265 2,380 kWh |
$230 44 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $220,245 Cost: $242,000 |
$9,425 | 220,440 | $15,820 | 2,987 | $117,000 | - | $78,000 | - | $9,425 220,440 kWh |
$15,820 2,987 kW-months/year |
$117,000 - $ |
$78,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $132,250 Cost: $179,100 |
$9,160 | 218,060 | $6,090 | 1,155 | $117,000 | - | - | - | $9,160 218,060 kWh |
$6,090 1,155 kW-months/year |
$117,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Primary Raw Material | Primary Product |