IAC logo
IAC Assessment: OR0442
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OR0442
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2003
Principal Product Cheese
NAICS 311513 - Cheese Manufacturing
SIC 2022 - Cheese, Natural And Processed
Sales $50,000,000-$100,000,000
# of Employees 60
Plant Area (Sq.Ft.) 0
Annual Production 42,536,000 Pounds
Production Hrs. Annual 5,616
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $376,349 8,863,440 kWh $0.04
Electricity Demand $66,874 18,576 kW-months/year $3.60
Electricity Fees $4,670 - $ -
Other Energy $293,815 56,668 MMBtu $5.18
TOTAL ENERGY COSTS $741,708
RECOMMENDED SAVINGS* $72,600 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,870
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Energy Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Other Energy Personnel Changes Primary Raw Material
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.2127 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM Savings:
$27,900
Cost:
$23,290
- - - - $27,900 5,850 - - - - -
-
kWh
-
-
kW-months/year
$27,900
5,850
MMBtu
-
-
$
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$21,500
Cost:
$11,700
$18,220 437,500 $3,280 912 - - - - - - $18,220
437,500
kWh
$3,280
912
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$11,250
Cost:
$1,340
$7,020 161,000 - - - - $670 - $3,560 - $7,020
161,000
kWh
-
-
kW-months/year
-
-
MMBtu
$670
-
$
$3,560
-
$
04: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$7,900
Cost:
-
$7,900 189,700 - - - - - - - - $7,900
189,700
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,470
Cost:
-
$3,010 68,000 $460 128 - - - - - - $3,010
68,000
kWh
$460
128
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
06: 2.4145 INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE Savings:
$580
Cost:
$1,400
$490 11,800 $90 25 - - - - - - $490
11,800
kWh
$90
25
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$72,600
Cost:
$37,730
$36,640 868,000 $3,830 1,065 $27,900 5,850 $670 - $3,560 - $36,640
868,000
kWh
$3,830
1,065
kW-months/year
$27,900
5,850
MMBtu
$670
-
$
$3,560
-
$
TOTAL IMPLEMENTED Savings:
$32,870
Cost:
$11,700
$29,130 695,200 $3,740 1,040 - - - - - - $29,130
695,200
kWh
$3,740
1,040
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Other Energy Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Other Energy Personnel Changes Primary Raw Material