Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2004 |
Principal Product | Margarine |
NAICS | 311225 - Fats and Oils Refining and Blending |
SIC | 2079 - Edible Fats And Oils, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 105,000,000 Pounds |
Production Hrs. Annual | 5,024 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $105,138 | 2,468,100 | kWh | $0.04 |
Electricity Demand | $32,531 | 6,738 | kW-months/year | $4.83 |
Electricity Fees | $8,556 | - | $ | - |
Natural Gas | $82,599 | 137,722 | MMBtu | $0.60 |
TOTAL ENERGY COSTS | $228,824 | |||
RECOMMENDED SAVINGS* | $35,297 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,097 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $8,887 Cost: $4,500 |
- | - | - | - | - | - | $8,887 | 39,083 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,887 39,083 Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $9,900 Cost: $2,770 |
- | - | - | - | $3,870 | 7,590 | $550 | 4,675 | $610 | 468,500 | $4,870 | - |
- - kWh |
- - kW-months/year |
$3,870 7,590 MMBtu |
$550 4,675 Tgal |
$610 468,500 gal |
$4,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,700 Cost: $2,030 |
- | - | - | - | $2,700 | 5,290 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,700 5,290 MMBtu |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,700 Cost: $5,900 |
$2,900 | 73,400 | $1,800 | 28 | - | - | - | - | - | - | - | - |
$2,900 73,400 kWh |
$1,800 28 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,910 Cost: $3,000 |
$1,890 | 46,850 | $1,020 | 14 | - | - | - | - | - | - | - | - |
$1,890 46,850 kWh |
$1,020 14 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $6,200 Cost: $1,500 |
$6,200 | 152,400 | - | - | - | - | - | - | - | - | - | - |
$6,200 152,400 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,297 Cost: $19,700 |
$10,990 | 272,650 | $2,820 | 42 | $6,570 | 12,880 | $9,437 | 43,758 | $610 | 468,500 | $4,870 | - | $10,990 272,650 kWh |
$2,820 42 kW-months/year |
$6,570 12,880 MMBtu |
$9,437 43,758 Tgal |
$610 468,500 gal |
$4,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,097 Cost: $18,200 |
$4,790 | 120,250 | $2,820 | 42 | $6,570 | 12,880 | $9,437 | 43,758 | $610 | 468,500 | $4,870 | - | $4,790 120,250 kWh |
$2,820 42 kW-months/year |
$6,570 12,880 MMBtu |
$9,437 43,758 Tgal |
$610 468,500 gal |
$4,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Ancillary Material Cost |