IAC logo
IAC Assessment: OR0569
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OR0569
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2011
Principal Product Manufactured Homes
NAICS 321992 - Prefabricated Wood Building Manufacturing
SIC 2451 - Mobile Homes
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 259,100
Annual Production 720 Units
Production Hrs. Annual 2,250
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $73,560 1,411,120 kWh $0.05
Electricity Demand $30,944 6,593 kW-months/year $4.69
Electricity Fees $15,154 - $ -
Natural Gas $1,224,498 128,346 MMBtu $9.54
TOTAL ENERGY COSTS $1,344,156
RECOMMENDED SAVINGS* $47,706 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $33,216
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$9,149
Cost:
$450
- - - - $9,149 1,130 - - -
-
kWh
-
-
kW-months/year
$9,149
1,130
MMBtu
-
-
$
02: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$5,650
Cost:
$700
$3,360 69,525 $2,290 371 - - - - $3,360
69,525
kWh
$2,290
371
kW-months/year
-
-
MMBtu
-
-
$
03: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM Savings:
$3,890
Cost:
$500
- - - - $4,390 540 $(-500) - -
-
kWh
-
-
kW-months/year
$4,390
540
MMBtu
$(-500)
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$517
Cost:
$517
$368 7,380 $149 24 - - - - $368
7,380
kWh
$149
24
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$17,900
Cost:
$58,500
$17,900 240,000 - - - - - - $17,900
240,000
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$10,600
Cost:
$38,900
$9,050 185,000 $1,550 252 - - - - $9,050
185,000
kWh
$1,550
252
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$47,706
Cost:
$99,567
$30,678 501,905 $3,989 647 $13,539 1,670 $(-500) - $30,678
501,905
kWh
$3,989
647
kW-months/year
$13,539
1,670
MMBtu
$(-500)
-
$
TOTAL IMPLEMENTED Savings:
$33,216
Cost:
$60,167
$21,628 316,905 $2,439 395 $9,149 1,130 - - $21,628
316,905
kWh
$2,439
395
kW-months/year
$9,149
1,130
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes