Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2013 |
Principal Product | Baked Goods |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 49 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 40,000,000 Pieces |
Production Hrs. Annual | 8,112 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $358,481 | 5,026,238 | kWh | $0.07 |
Electricity Demand | $65,651 | 8,856 | kW-months/year | $7.41 |
Electricity Fees | $33,247 | - | $ | - |
Natural Gas | $139,559 | 20,853 | MMBtu | $6.69 |
TOTAL ENERGY COSTS | $596,938 | |||
RECOMMENDED SAVINGS* | $36,138 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,099 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $11,140 Cost: $5,000 |
$(-10) | (-136) | - | - | - | - | $7,488 | 192,000 | $3,662 | - | - | - |
$(-10) (-136) kWh |
- - kW-months/year |
- - MMBtu |
$7,488 192,000 lb |
$3,662 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,040 Cost: $2,913 |
$1,967 | 26,080 | $5 | 1 | - | - | - | - | $69 | - | $999 | - |
$1,967 26,080 kWh |
$5 1 kW-months/year |
- - MMBtu |
- - lb |
$69 - $ |
$999 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $11,262 Cost: $36,000 |
$7,886 | 104,527 | $1,283 | 163 | - | - | - | - | - | - | $2,093 | - |
$7,886 104,527 kWh |
$1,283 163 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$2,093 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $3,635 Cost: $8,000 |
- | - | - | - | - | - | $3,948 | 100 | $(-313) | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,948 100 lb |
$(-313) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,364 Cost: $17,632 |
- | - | - | - | $5,364 | 902 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,364 902 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $991 Cost: $95 |
$991 | 13,140 | - | - | - | - | - | - | - | - | - | - |
$991 13,140 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY |
Savings: $706 Cost: $448 |
$706 | 9,355 | - | - | - | - | - | - | - | - | - | - |
$706 9,355 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,138 Cost: $70,088 |
$11,540 | 152,966 | $1,288 | 164 | $5,364 | 902 | $11,436 | 192,100 | $3,418 | - | $3,092 | - | $11,540 152,966 kWh |
$1,288 164 kW-months/year |
$5,364 902 MMBtu |
$11,436 192,100 lb |
$3,418 - $ |
$3,092 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,099 Cost: $41,543 |
$9,573 | 126,886 | $1,283 | 163 | - | - | $7,488 | 192,000 | $3,662 | - | $2,093 | - | $9,573 126,886 kWh |
$1,283 163 kW-months/year |
- - MMBtu |
$7,488 192,000 lb |
$3,662 - $ |
$2,093 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |