Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2014 |
Principal Product | Plywood and LVL |
NAICS | 321212 - Softwood Veneer and Plywood Manufacturing |
SIC | 2436 - Softwood Veneer And Plywood |
Sales | $50,000,000-$100,000,000 |
# of Employees | 317 |
Plant Area (Sq.Ft.) | 450,000 |
Annual Production | 120,000,000 Units |
Production Hrs. Annual | 4,992 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,128,644 | 21,416,400 | kWh | $0.05 |
Electricity Demand | $294,462 | 40,898 | kW-months/year | $7.20 |
Electricity Fees | $2,520 | - | $ | - |
LPG | $173,372 | 9,592 | MMBtu | $18.07 |
TOTAL ENERGY COSTS | $1,598,998 | |||
RECOMMENDED SAVINGS* | $352,579 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $29,475 Cost: $7,174 |
$29,475 | 561,751 | - | - | - | - | - | - | - | - |
$29,475 561,751 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,287 Cost: $1,628 |
$6,287 | 119,816 | - | - | - | - | - | - | - | - |
$6,287 119,816 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $56,191 Cost: $56,191 |
- | - | - | - | - | - | - | - | $56,191 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$56,191 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $14,844 Cost: $15,843 |
$12,337 | 234,090 | $2,507 | 348 | - | - | - | - | - | - |
$12,337 234,090 kWh |
$2,507 348 kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $23,961 Cost: $9,068 |
$23,961 | 454,665 | - | - | - | - | - | - | - | - |
$23,961 454,665 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $181,002 Cost: $170,561 |
$130,333 | 2,473,114 | $17,393 | 2,416 | $3,381 | - | $29,895 | - | - | - |
$130,333 2,473,114 kWh |
$17,393 2,416 kW-months/year |
$3,381 - $ |
$29,895 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $40,819 Cost: $43,800 |
$45,531 | 863,970 | $(-4,712) | (-654) | - | - | - | - | - | - |
$45,531 863,970 kWh |
$(-4,712) (-654) kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $352,579 Cost: $304,265 |
$247,924 | 4,707,406 | $15,188 | 2,110 | $3,381 | - | $29,895 | - | $56,191 | - | $247,924 4,707,406 kWh |
$15,188 2,110 kW-months/year |
$3,381 - $ |
$29,895 - $ |
$56,191 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Water Consumption |