Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2023 |
Principal Product | Formaldehyde Resins |
NAICS | 325211 - Plastics Material and Resin Manufacturing |
SIC | 2821 - Plastics Materials And Resins |
Sales | $50,000,000-$100,000,000 |
# of Employees | 27 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 78,736 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $480,614 | 9,684,680 | kWh | $0.05 |
Electricity Demand | $107,841 | 18,124 | kW-months/year | $5.95 |
Electricity Fees | $22,047 | - | $ | - |
Natural Gas | $455,134 | 46,380 | MMBtu | $9.81 |
TOTAL ENERGY COSTS | $1,065,636 | |||
RECOMMENDED SAVINGS* | $48,034 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,566 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $22,304 Cost: $25,167 |
$19,906 | 373,256 | $2,398 | 511 | - | - | - | - | - | - |
$19,906 373,256 kWh |
$2,398 511 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $9,363 Cost: $1,352 |
$8,354 | 156,645 | $1,009 | 215 | - | - | - | - | - | - |
$8,354 156,645 kWh |
$1,009 215 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,514 Cost: $8,385 |
$4,077 | 76,552 | $997 | 213 | - | - | $823 | - | $1,617 | - |
$4,077 76,552 kWh |
$997 213 kW-months/year |
- - $ |
$823 - $ |
$1,617 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,801 Cost: $7,178 |
- | - | - | - | $5,801 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,801 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,740 Cost: $3,039 |
$1,740 | 32,630 | - | - | - | - | - | - | - | - |
$1,740 32,630 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,312 Cost: $5,390 |
$72 | 1,359 | - | - | - | - | $1,240 | - | - | - |
$72 1,359 kWh |
- - kW-months/year |
- - $ |
$1,240 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,034 Cost: $50,511 |
$34,149 | 640,442 | $4,404 | 939 | $5,801 | - | $2,063 | - | $1,617 | - | $34,149 640,442 kWh |
$4,404 939 kW-months/year |
$5,801 - $ |
$2,063 - $ |
$1,617 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,566 Cost: $16,814 |
$5,889 | 110,541 | $997 | 213 | - | - | $2,063 | - | $1,617 | - | $5,889 110,541 kWh |
$997 213 kW-months/year |
- - $ |
$2,063 - $ |
$1,617 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost |