Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2024
Principal Product Steel
NAICS 331221 - Rolled Steel Shape Manufacturing
SIC 3316 - Cold Finishing Of Steel Shapes
Sales $100,000,000-$500,000,000
# of Employees 260
Plant Area (Sq.Ft.) 521,982
Annual Production 961,950 Tons
Production Hrs. Annual 8,472
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,746,314 58,556,797 kWh $0.05
Electricity Demand $335,612 80,854 kW-months/year $4.15
Electricity Fees $2,520 - $ -
Natural Gas $1,682,677 759,091 MMBtu $2.22
TOTAL ENERGY COSTS $4,767,123
RECOMMENDED SAVINGS* $89,032 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION Savings:
$5,407
Cost:
-
$5,407 115,294 - - $5,407
115,294
kWh
-
-
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,219
Cost:
$9,036
$3,705 78,995 $514 124 $3,705
78,995
kWh
$514
124
kW-months/year
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$77,631
Cost:
$300,000
$51,237 1,092,480 $26,394 6,360 $51,237
1,092,480
kWh
$26,394
6,360
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,775
Cost:
$10,104
$1,577 33,619 $198 48 $1,577
33,619
kWh
$198
48
kW-months/year
TOTAL RECOMMENDED Savings:
$89,032
Cost:
$319,140
$61,926 1,320,388 $27,106 6,532 $61,926
1,320,388
kWh
$27,106
6,532
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand