IAC logo
IAC Assessment: RU0102
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: RU0102
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Rutgers, State Univ. of NJ
Assessment Year 1990
Principal Product FIRE & INTRUSION SYSTEMS
NAICS n/a
SIC 3669 - Communications Equipment, Nec
Sales $50,000,000-$100,000,000
# of Employees 370
Plant Area (Sq.Ft.) 0
Annual Production 650,000 Pieces
Production Hrs. Annual 4,720
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $252,340 2,898,886 kWh $0.09
Natural Gas $17,917 3,319 MMBtu $5.40
Fuel Oil #2 $2,205 281 MMBtu $7.85
TOTAL ENERGY COSTS $272,462
RECOMMENDED SAVINGS* $24,192 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,441
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$504
Cost:
-
$504 5,862 - - $504
5,862
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,462
Cost:
$631
$2,462 28,136 - - $2,462
28,136
kWh
-
-
MMBtu
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,881
Cost:
$2,500
$5,881 - - - $5,881
-
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$632
Cost:
$302
$632 7,327 - - $632
7,327
kWh
-
-
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,466
Cost:
-
$4,466 51,290 - - $4,466
51,290
kWh
-
-
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$917
Cost:
-
$917 10,551 - - $917
10,551
kWh
-
-
MMBtu
07: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$9,330
Cost:
$34,669
$4,755 54,807 $4,575 847 $4,755
54,807
kWh
$4,575
847
MMBtu
TOTAL RECOMMENDED Savings:
$24,192
Cost:
$38,102
$19,617 157,973 $4,575 847 $19,617
157,973
kWh
$4,575
847
MMBtu
TOTAL IMPLEMENTED Savings:
$13,441
Cost:
$3,433
$13,441 86,753 - - $13,441
86,753
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas